Download Print this page

Hunter MD506-01 Installation Instructions And Use & Care Manual

Led ceiling fan

Advertisement

Quick Links

www.ventiladoreshunter.com.br
ENGLISH
MD506-01 • 09/19/14 • © Hunter Fan Company

Advertisement

loading
Need help?

Need help?

Do you have a question about the MD506-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hunter MD506-01

  • Page 1 ENGLISH MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 2 Important Instructions: Keep Instructions for future use...
  • Page 3 7 feet Ladder Assembling the Top Housing Downrod Wiring Canopy Operation, Blades Light Kit Remote Control Maintenance & Cleaning Troubleshooting Warranty Statement MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 4 Check box to see accessory light kits. electrical codes. If you are unfamiliar with wiring, use a qualified Select a downrod length fan weight electrician. c.2 - Use only Hunter replacement parts. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 5 Ladder Pliers Wire Strippers Screwdrivers Power Drill 3.5 mm Drill 8 mm Drill Bit Hammer (optional) Bit (optional) (optional) (optional) If mounting to a support structure, you will also need these tools. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 6 The support structure must be able to support 5 Carefully choose the installation location times the weight of the fan. The weight of the fan is that allows for optimal air flow. located on the product packaging. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 7 To avoid possible electrical shock, before installing your fan, disconnect the power by Refer to warning w.1 on pg. 2 turning off the circuit breakers to the outlet box associated with the wall switch location. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 8 Make certain the housing sits flat on the adapter. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 9 Steps 1-5 to remove standard downrod pipe Longer Downrod for angled ceilings or ceilings 3 m or higher Shorter Downrod for fans installed close to ceiling Steps 6-10 to reassemble with new pipe MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 10 20 cm extending from the top turns) until it stops. DO NOT HAND TIGHTEN. of the downrod. 20 cm 1 cm If the setscrew is not tightened securely, the fan may fall. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 11 DO NOT PICK THE FAN UP BY THE CANOPY Put the wires and downrod through the canopy. Let the canopy sit loosely on top of the fan. OR WIRES. Place the downrod ball into the slot in the ceiling bracket. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 12 Spread the wires apart, with the grounded wires on one side of Refer to CAUTION c.1 on pg. 2 the outlet box and the ungrounded wires on the other side of the outlet box. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 13 Insert the two canopy screws lifted into place, the canopy fits into the screw holes are aligned. found in the hardware bag. the hanging bracket as shown. Note: Fan style may vary. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 14 Your blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. For cleaning the fan, use soft brushes or cloths to prevent scratching. Cleaning agents may damage the finishes. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 15 MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 16 Make sure the light kit is securely attached to the mounting plate. Failure to properly secure all three assembly screws could result in the light fixture falling. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 17 Push excess wiring into the switch housing through the wire slot. hardware bag, through the slots, not the screw holes. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 18: Operation Instructions

    Align the three holes in the trim ring with the three holes in the light kit. Install and See next page for fan securely tighten all three globe assembly operation instructions. screws, found in the hardware bag. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 19 Note: For rocker-style cover plates, fan, wait 1 minute then try again. If break off the tabs by pushing outward. Turn Power using the transmitter with multiple fans, repeat this process for each fan. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 20 Cleaning the lights will be completely off. assembly screws, the glass, and trim ring. Flip products may damage the finishes. the black switch to change the direction. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 21 9. • Install a fresh battery. • Check the plug connection in the switch housing. Transmitter only works when held at close range • Install a fresh battery. MD506-01 • 09/19/14 • © Hunter Fan Company...
  • Page 22 1. Warranty repairs shall only be performed by an Authorized Service Center appointed by Hunter Fan do Brasil, which 1. Hunter Ceiling Fans are warranted by Hunter Fan do Brasil for a period of 1 (one) year from the date of purchase by the provides specialized technicians and original parts, guaranteeing the service provided.