Electrical Data - Nordyne R8HE Series Installation Instructions Manual

Single package gas heating / electric cooling 3-phase & single phase (revision a)
Hide thumbs Also See for R8HE Series:
Table of Contents

Advertisement

MODEL
HEATING
NUMBER
INPUT
R8HE / PPG3HE
(BTUH)
HIGH - 60,000
X24K060XA
LOW - 39,000
HIGH - 60,000
X30K060XA
LOW - 39,000
HIGH - 80,000
X36K080XA
LOW - 52,000
HIGH - 80,000
X42K080XA
LOW - 52,000
HIGH - 96,000
X48K096XA
LOW - 62,400
HIGH - 96,000
X60K096XA
LOW - 62,400
MODEL
HEATING
NUMBER
INPUT
R8HE / PPG3HE
(BTUH)
HIGH - 80,000
R8HE-X36C080X
LOW - 52,000
HIGH - 80,000
R8HE-X36D080X
LOW - 52,000
HIGH - 96,000
R8HE-X48C096X
LOW - 62,400
HIGH - 96,000
R8HE-X48D096X
LOW - 62,400
HIGH - 96,000
R8HE-X60C096X
LOW - 62,400
HIGH - 96,000
R8HE-X60D096X
LOW - 62,400
NOTES: LRA = Locked Rotor Amps; RLA = Rated Load Amps
COPPER WIRE SIZE — AWG
(1% VOLTAGE DROP)
SUPPLY WIRE LENGTH-FEET
200
150
100
6
8
10
4
6
8
4
6
8
4
4
6
3
4
6
3
4
6
2
3
4
2
3
4
2
3
4
1
2
3
NOTE: Wire Size based on N.E.C. for 60° type copper conductors.
Table 17. Copper Wire Size

Electrical Data

SINGLE PHASE MODELS
INDUCER
VOLTAGE
NOMINAL
MOTOR
RANGE
ELECTRICAL
SUPPLY
RLA
MIN.
0.30
208/230-1-60 187
0.30
208/230-1-60 187
0.30
208/230-1-60 187
0.30
208/230-1-60 187
0.30
208/230-1-60 187
0.30
208/230-1-60 187
THREE PHASE MODELS
INDUCER
VOLTAGE
NOMINAL
MOTOR
RANGE
ELECTRICAL
SUPPLY
RLA
MIN.
0.30
208/230-3-60 187
0.30
460-3-60
414
0.30
208/230-3-60 187
0.30
460-3-60
414
0.30
208/230-3-60 187
0.30
460-3-60
414
Table 16. Electrical Data.
SUPPLY CIRCUIT
AMPACITY
50
14
15
12
20
10
25
10
30
8
35
8
40
6
45
6
50
6
55
4
60
COMPRESSOR
FAN
AMPS
MAX.
RLA
LRA
253
12.8
58
1.0
253
15.7
73
1.5
253
18.6
79
1.5
253
22.1
109
1.5
253
24.3
117
1.5
253
29.4
134
1.5
COMPRESSOR
FAN
AMPS
MAX.
RLA
LRA
253
11.6
73
1.5
506
6.4
38
0.6
253
15.3
83
1.5
506
6.9
41
0.6
253
17.8
110
1.5
506
8.6
52
0.6
THERMOSTAT
WIRE GAUGE
2-WIRE
(HEATING)
24
22
20
18
Table 18. Thermostat Wire Gauge
MAXIMUM
BLOWER
MINIMUM
OVER-
MOTOR
CIRCUIT
CURRENT
AMPS
AMPACITY
PROTECTION
5.4
22.4
35
5.4
26.5
40
7.0
31.8
50
7.0
36.1
55
7.0
38.8
60
7.0
45.2
70
MAXIMUM
BLOWER
MINIMUM
OVER-
MOTOR
CIRCUIT
CURRENT
AMPS
AMPACITY
PROTECTION
7.0
23.0
30
3.3
11.9
15
7.0
27.6
40
3.3
12.5
15
7.0
30.7
45
3.3
14.7
20
RECOMMENDED T-STAT WIRE
LENGTH (UNIT TO T-STAT)
5-WIRE
(HEATING / COOLING)
55
25
90
45
140
70
225
110
35

Hide quick links: