Troubleshooting - Horizon Fitness Titan XP90 Installation And Operation Manual

Hide thumbs Also See for Titan XP90:
Table of Contents

Advertisement

Machine Won't Run
Machine Won't Run
Cannot Start Dehumidifier
Cannot Start Dehumidifier
Loud Noise
Loud Noise
Trouble Code E:1
Trouble Code E:3
a.
6.
Trouble Code: HI or LO
7.
Trouble Code E:4
If a pump alarm is provided on display:
1. Reset the unit by disconnecting the power cord and then reconnecting it.
NOTE: Unit will not function until error code has been cleared.
2. Manually check to see if pump is operational by pressing the drain button. Check if the pump ener-
gizes and de-energizes properly and if any water purged from the system. If you haven't cleaned the
system recently, check the discharge line for an obstruction then clean the balance of pump system per
instructions in "Maintenance" section on page 8.
3. Replace hoses and/or pump, if maintenance alone is not sufficient.

Troubleshooting

Symptom
Power Supply
Room Temperature Over 105°
(Display HI) or Below 33°
LO)
Air Filter is Clogged
Air Inlet or Outlet is Jammed
Machine Is Not Level
Filter Mesh is Jammed
E1=Humidity Sensor Issues
The coil sensor has failed
Room Temperature Over 105°
Below 33°
Pump has failed
Pump Alarm- Error Code E2/E4
Cause
Verify that there is power to the outlet and
that the plug is properly installed in outlet
The unit is outside the operating
F
(Display
temperature range. Modify the room
F
conditions so the temperature is between
33°-105°
Clean the filter mesh according to
instructions listed in manual.
Clear the blockage from inlet or outlet.
Move the dehumidifier to flat, firm ground.
Clean the filter mesh according to
instructions listed in manual.
Check to ensure that wire is connected at
both ends. If no issues are visible, the
sensor may be faulty.
Replace the sensor
or
The unit is outside the operating
F
(Display LO)
temperature range. Modify the room
F
conditions so the temperature is between
33°-105°
room is not out of temperature range,
replace defective sensor.
Verify the pump is working. If so, unplug
the unit for two minutes, then restart.
11
Solution
and operation will commence.
F
and operation will commence. If
F