Flex Duct Installation
Rotate the flex duct counter-
clockwise or simply position
Symptom
Machine Won't Run
Machine Won't Run
Cannot Start Dehumidifier
Cannot Start Dehumidifier
Loud Noise
Loud Noise
Trouble Code E:1
Trouble Code E:3
6.
Trouble Code: HI or LO
7.

Troubleshooting

Cause
Power Supply
Room Temperature Over 105°
(Display HI) or Below 33°
(Display
F
LO)
Air Filter is Clogged
Air Inlet or Outlet is Jammed
Machine Is Not Level
Filter Mesh is Jammed
E1=Humidity Sensor Issues
The coil sensor has failed
Room Temperature Over 105°
Below 33°
(Display LO)
F
10
Flex Duct Removal
Rotate flex duct clockwise or
remove wire tie and slide duct
Solution
Verify that there is power to the outlet and
that the plug is properly installed in outlet
The unit is outside the operating
F
temperature range. Modify the room
conditions so the temperature is between
33°-105°
and operation will commence.
F
Clean the filter mesh according to
instructions listed in manual.
Clear the blockage from inlet or outlet.
Move the dehumidifier to flat, firm ground.
Clean the filter mesh according to
instructions listed in manual.
Check to ensure that wire is connected at
both ends. If no issues are visible, the
sensor may be faulty.
Replace the sensor
or
The unit is outside the operating
F
temperature range. Modify the room
conditions so the temperature is between
33°-105°
and operation will commence. If
F
room conditions are within temperature
range, replace defective sensor.