Transition to LO work profile
with decreasing speed: 8 kn
Range: OFF - 40 (kn)
Default: OFF
Thruster inhibit speed
This feature will block the thruster from running above a set vessel speed. It is a safety feature
to prevent, especially electrical on/off thrusters, from overheating if out of water or for
instance a planing boat or in rough weather.
When the speed exceed the set limit the truster indication will change as shown below.
¼ Note:
The Thruster inhibit limit will only apply when speed source is Log or SOG, not if the
speed is set manually.
Range: 1 - 40 (kn)
Default: 6 (kn)
Low speed limit
Sets the limit for the low vessel speed alarm.
An alarm occurs when the vessel's speed goes below the selected limit.
Range: 1 - 20 (kn)
Default: 1 (kn)
Init rudder
Defines how the system moves the rudder when switching from power steering to an
automatic mode:
-
Midships moves the rudder to zero position.
-
Actual maintains the rudder offset, and use this as trim value (bumpless transfer)
¼ Note:
Actual is only available with rudder feedback signal available.
Default: Midships
System configuration |
AP70/AP80 Installation Manual
Transition to HI work profile with
increasing speed: 10 kn
Transition speed set to 9 kn
Thruster(s) in use
Thrusters unavailable when
speed exceed inhibit limit
| 53