U_CTRL
EXT
READY
INT
ON
U_CTRL
EXT
READY
INT
ON
32 |
Voltage control with external reference, positive variable
Normally used to control proportional valves with 12 V and 24 V power.
Available control range will be from 5-95% of external voltage. Control signal will be positive
variable relative the external reference voltage minus.
Zero output = External power/2.
Zero setting and control range output at U_CTRL can be adjusted in dockside setup. See
"Rudder feedback/tunnel thruster feedback calibration" on page 51 .
For Analog output, external voltage, the switch must be set to EXT.
STEERING GEAR
SIGNAL
Analog output, current
A 4-20 mA control signal is available. Rudder zero current and control range can be adjusted
in the Dockside setup (ref. page 55).
Rudder zero current and control range can be adjusted in dockside setup. See "Rudder
feedback/tunnel thruster feedback calibration" on page 51.
For Analog output, current, the switch must be set to INT.
STEERING GEAR
4-20 mA
Wiring |
AP70/AP80 Installation Manual
AD80 BOARD
U_CTRL
EXT
READY
INT
ON
UI_CTRL
AD80 BOARD
U_CTRL
EXT
READY
INT
ON
UI_CTRL
AD80, AC80A
or AC85
Computer
12-24 V DC
EXTERNAL STEERING GEAR SUPPLY
AD80, AC80A
or AC85
Computer