9.3.4 Defective Igniter Fuse

The igniter is defective: Test the resistance (ohms, Ω) with a multimeter. If the value
is near zero, replace the igniter.
The wiring harness shorted. Inspect the wiring and replace any defective wire and or
connector. Make sure the wires are not shorted to the stove frame Go to the
troubleshooting page (see Section 9.2: Testing Components) and follow instructions
for component check. Test the igniter to see if it glows. It should take no longer than
two minutes.

9.3.5 Auger Fuse

The auger is jammed or auger motor failed. Go to the troubleshooting page (see
Section 9.2: Testing components) on the LCD touch screen and test auger motors. If
one of the motors is not running check if motor is defective or jammed.
NOTE : IF THE HOPPER AUGER MOTOR FAILED OR THE HOPPER AUGER IS
JAMMED, TO AVOID PELLET SPILLAGE, EMPTY THE HOPPER OF ITS CONTENTS
BEFORE EXECUTING THE FOLLOWING TESTS.
o If the auger motor is defective, check to make sure that electrical connections are
not loose. If the connections are good, remove the faulty auger motor from its
auger housing and retest the motor separately still using the troubleshooting test
mode. Make sure the hopper lid is closed. If the motor functions, the auger may be
jammed by a foreign object. If no signs of blockage are found, call your dealer or a
service technician to perform a complete testing.