Xcp Issues Fixed In Releases Earlier Than Xcp 1093 - Fujitsu SPARC Enterprise M3000 Product Notes

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

XCP Issues Fixed in Releases Earlier Than XCP
1093
TABLE 6
XCP Issues Fixed in Releases Earlier Than XCP
TABLE 6
ID
Description
RTIF1-
While XSCF is running, a process may go
070418-009
down, a watchdog timeout may occur, or a
hang-up may occur. After this, XSCF may
reset.
RTIF1-
While XSCF is running, watchdog timeout
070528-002
may occur and XSCF may reboot.
RTIF1-
When remote power control mode of
070824-001
interlocking mechanism for power supply to
domain, is enabled, after the motherboard unit
is replaced, the interlocking for power supply
by RCI cannot work.
RTIF1-
The snmp daemon might quit.
071102-002
RTIF1-
After set the Daylight Saving Time by using
080725-004
the XSCF shell, XSCF Web does not show the
correct time in the Logs menu.
RTIF1-
The error log "XSCF FMEM write error"
081006-001
recorded and the firmware update might fail.
RTIF1-
In the setemailreport(8) command, when
081006-002
you specified over 255 characters in the SMTP
address, an error results.
RTIF1-
During the domain operation, after the XSCF
081006-003
reset due to the XSCF unit failure, the
hardware status shows Deconfigure in the
status of CPU and memory.
RTIF1-
During the firmware update, there might be
081006-004
the following output message and a XSCF
panic might occur.
kernel BUG in jffs2_do_read_inode
at fs/jffs2/readinode.c:XXX!
lists XCP issues that have been fixed in releases earlier than XCP 1093.
1093
Workaround
Check that XSCF is started. If not started, stop
the domain and then execute the system power
off/on (AC OFF/ON). To turn on the system
power that you turned off, wait at least 30
seconds before power-on.
Check that XSCF is started. If not started, stop
the domain and then execute the system power
off/on (AC OFF/ON). To turn on the system
power that you turned off, wait at least 30
seconds before power-on.
After the motherboard unit is replaced,
configures the RCI again and sets the remote
power control mode.
To restart the snmp daemon, issue the
command setsnmp enable.
No workaround is available.
Use the showlogs(8) command of the XSCF
shell.
Power off (AC OFF) the system, and power on
(AC ON) again. Then, re-execute the firmware
update.
Do not specify over 255 characters in the SMTP
address.
Replace the motherboard unit only. When no
failure found on the memory, you do not need
to replace the memory.
Reset XSCF and use the flashupdate(8)
command to retry the firmware update.
Information About Software
19

Advertisement