15. Fuel Cell Storage
Always store fuel cells where they will not be
exposed to an open flame, sparks or temperatures
above 120 degrees F (48 degrees C).
16. ALWAYS store the tool with the fuel cell removed.
17. Keep the tool clean.
18. Keep your hands clear of the work area surface.
A fastener may exit at an angle unexpectedly and
cause injury.
BATTERY CELL AND CHARGER
CHEMICAL/EXPLOSION HAZARD
Read ALL instructions before charging or using
the battery. Failure to follow ALL instructions may
result in fire, severe burns and/or release of toxic
materials.
1.
Keep the battery charger upright for proper opera-
tion.
2.
Only charge the battery indoors.
3.
Do not charge the battery when the battery tempera-
ture is below 40 degrees F (5 degrees C).
4.
Do not use a defective battery charger, one that
overheats and/or smokes when plugged in.
5.
Plug the battery charger into a 120V AC outlet only.
A blue light indicates that power is on and that char-
ger circuit is ready.
DANGER
WARNING
DANGER
TRAKFAST REPAIR MANUAL
SAFETY INSTRUCTIONS
6.
Insert the battery, contact side down, into the
charger and depress red button. The green light will
go out and the red light will come on, indicating the
battery is charging.
7.
The green light comes on again when the battery
is fully charged. The time required to fully charge a
battery:
First charge
Completely Discharged
Partially Discharged
8.
Do not allow metal objects to come in contact with
the battery terminals.
9.
Do not puncture or attempt to open the battery cell.
10. Do not store the battery in location where tempera-
tures exceed 120 degrees F (48 degrees C).
11. Do not incinerate the Battery.
FUEL CELL
EXPLOSION/FIRE HAZARD
Read all safety instructions before using or handling the
fuel cell. Failure to follow ALL instructions may result in
explosion or fire. This may cause severe personal injury
or property damage. Keep the fuel cell away from heat,
sparks and open flame. Do not puncture or attempt to
open the fuel cell; it is non-refillable. Do not incinerate,
reclaim or recycle the fuel cell. Exposure to temperature
above 120 degrees F (48 degrees C) may cause the fuel
cell to burst, releasing flammable gas. Do not smoke
while installing/operating the metering valve. Never
spray toward the face or eyes. Do not inhale the spray.
Keep out of the reach of children. Store fuel cell(s) in
well ventilated areas only.
Nickel Cadmium Rechargeable Battery.
Must be recycled or disposed of prop-
erly. NOTE: DEAD BATTERY MUST BE
RETURNED TO YOUR LOCAL TRAKFAST
DISTRIBUTOR FOR PROPER DISPOSAL.
24 hours
3 hours
Depends on discharge
level of battery
DANGER
WARNING
5
Rev. 09/07

Advertisement

Table of Contents
loading

Table of Contents