MANUAL IGNITION/OPERATION
manually control operation during an emergency (i.e. igniter failure, when using a 502H battery
backup, or when using certain generators.)
Room Temperature Mode: This setting will produce a room
temperature of 70 degrees with the distribution blower at
medium speed.
Manual Stove Temperature Mode
WARNING: HIGH VOLTAGE
Disconnect power before opening cover.
This setting will produce a large viewing fire without
a distribution blower operating.
The Accentra Pellet Stove is capable of manual operation. This also allows the operator to
The unit can be switched between "AUTO" and "MANUAL" at any time during operation.
Fig. 5
Fig. 6
NOTE: When starting the unit in the "AUTO"
mode and switching to "MANUAL", the fire must be
large enough to start the distribution blower. The start-
ing of the blower is a signal that the start cycle is com-
pleted and the fire will not go out.
Ignitor Switch to "MANUAL"
Room Temperature Mode
The fire will have to be lit with starting gel and a match,
or started automatically, see "Automatic Operation". Turn
to "Manual" position when the fire is established.
The difference between "AUTO" Room Temperature
Mode and "Manual" Room Temperature Mode is that the
fire will not go out as the room temperature goes above the
control board setting. The unit can only go to low burn and
will remain there until it runs out of fuel or until more heat is
needed and the feed rate increases. Feed rate adjustments
and dial settings are the same as "AUTO" settings.
Ignitor Switch to "MANUAL"
Stove Temperature Mode
The advantage of this mode is to allow the operator to
have a large viewing fire without blowing extra heat into the
room.
During operation, with the temperature dial set at #5
or less, the distribution fan will not operate. A #5 on the
temperature dial and a #5 on the feed adjuster is approxi-
mately 80% output. It is not necessary to operate the distri-
bution blower below this point. Therefore, there can be a
higher feed rate ( a larger viewing fire) without an excess of
hot air blowing into the room.
An example of when to use the Manual Stove Tem-
perature Mode is if you want to watch a large fire and the
room is aleady up to temperature. The Stove Temperature
Mode allows you to have a larger fire and a lower sound
level, without the distribution blower.
NOTE: During the use of this mode, if you keep
increasing the temperature dial setting to increase the
fire size, the distribution blower will automatically come
on when the ESP Temperature reaches 350
output.
o
F, or 81%