Maintenance - Harman Stove Company Accentra Owner's Manual

Cast iron pellet stove
Table of Contents

Advertisement

Maintenance - Cleaning Glass on View Door
The unit should be out and cool to clean the door glass. It may not always be possible to allow the unit
to cool off before cleaning. Therefore, if the unit is turned to the lowest setting about 1 hour before cleaning, it
will make it possible to clean the glass with the unit in operation.
Any glass cleaner with a high amonia content will work the best. Use only non-synthetic cleaning rags
such as cotton or paper towels.
CAUTION: Take care when spraying cleaner on the side surface of the glass. The glass may be hot
enough to cause undesirable fumes to fill the area around the unit very rapidly. Gloves and eye
protection are recommended.
Control door
finger hole
HI-LO Distribution blower speed
range switch
Inspect the hopper lid sponge gasket. It is important to
maintain a good hopper lid seal.
Fig. 34
Do not allow pellets or sawdust to remain
on the hopper lip after filling.
Inspect door gasket during
cleaning and inspection
Draft Meter hex plug
Glass Gasket
Replace glass
only with high
t e m p e r a t u r e
ceramic glass.

Hide quick links: