Uv Hood Wiring - GAYLORD Ultima Vent GX2-UV Technical Manual

Non water-wash ventilators
Table of Contents

Advertisement

PC.
DESCRIPTION
NO.
CR20 Contactor
CR21,
Control Relay
23,24
Socket
Control Relay
CR22
Socket
LT1
Indicator Light - Green
LT2
Indicator Light - Yellow
LT3
Indicator Light - Red
DS
UV Access Door Switch
PS
UV Pressure Switch
GEM Gaylord Extractor Monitor
UVP UV Plug - Female
CF
Cooling Fan

UV HOOD WIRING

20
21
22
23
UV Hood T erminal Schedule
GAYLORD
PART NO.
Te rm ina l
30529
L1
Main Power Connection : Hot
L2
Main Power Connection : Neutral
11399
1U
Output - "UV System On"
11413
2U
Output - "UV Lamp Failure
3U
Output - "UV Safety Interlock Activated" (Red)
10283
5U
120VAC Neutral Leg
6U
Switched Power for UV Lamp Circuit
10295
P1,P2
Terminals for Pressure Switch #1
12512
D1,D2
Terminals for UV Access Door Switch #1
19162
G1,G2
Terminals for Gaylord Extractor Monitor (GEM)
12510
D3,D4
Terminals for UV Access Door Switch #2
19355
1A
UV Controller - Summary Alarm - N/C
19365
3A
UV Controller - Summary Alarm - Common
19427
4A
UV Controller - Input Power - Ground
16903
5A
UV Controller - Input Power - Hot
30424
6A
UV Controller - Input Power - Neutral
26
24
GEM
De scription
Type
120VAC
0 V
(Green) 120VAC
(Yellow) 120VAC
120VAC
0 V
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
0 V
120VAC
0 V