■ Optical Parts Disassemblies

Before taking this procedure, remove Cabinet Top , Cabinet Front and Main Board following to the "Mechanical
Disassemblies".
Disassembly requires a 2.0mm hex wrench.
z
Projection Lens removal
1
Remove 4 screws (M2.5x8) and remove the Projection Lens.
x
Integrator Lens-In disassembly
1
A
Remove 2 screws
(M2.5x5) and pull the Integrator Lens-In ass'y upward.
2
B
Unhook 4 stoppers
and then take the Lens off from the holder.
A
A
Fig.2-
Integrator Lens
* Lens should be placed as the
rugged surface side comes to
the holder side.
1
-12-
Fig.1
B
Stoppers
B
Stoppers
Fig.2-
2