Electrical Adjustments; Service Adjustment Menu Operation - Sanyo PLC-XU47 Service Manual

Hide thumbs Also See for PLC-XU47:
Table of Contents

Advertisement

■ Electrical Adjustments

● Service Adjustment Menu Operation
To enter the service mode
To enter the "Service Mode", press and hold the MENU and INPUT buttons on the projector at the same time for
more than 3 seconds. The service menu appears on the screen as follows.
To adjust service data
Select the adjustment item no. by pressing the pointer UP or DOWN button, and change the data value by press-
ing the VOLUME – or VOLUME + button. Refer to the "Service Adjustment Data Table" for further description of
adjustment item no. and data value.
To exit the service mode
To exit the service mode, press the POWER ON-OFF button on the projector or remote control unit.
ON - OFF
INPUT
AUTO SET UP
SELECT
MENU
● Memory IC Replacement
IC1841 on the main board stores the data for the serv-
ice adjustments, and should not be replaced except for
the case of defective device.
If replaced, the re-adjustments are required following to
the "Electrical Adjustments".
The data of lamp replacement counter is stored in the
IC1841.
Please note that the lamp replace counter will be reset
when the memory IC (IC1841) is replaced.
(Lamp replace counter cannot be set to the previous
value.)
● Caution to memory IC replacement
When IC1841 is replaced with new one, the CPU
writes down the default data of the service adjustments
to the replaced IC as the mentioned on the service
adjustment table. As these data are not the same data
as factory shipped data, it should be required to per-
POWER
WARNING
LAMP
REPLACE
Fan1Speed
Service Mode
Computer
70
100
TempA
TempB
32.10
43.21
Fan2Speed
97
105
form the re-adjustments following to the "Electrical
Adjustments".
Please note that in this case the lamp replace counter
will be reset.
● Caution of Main Board replacement (in the case
IC1841 is not defective)
When the main board is replaced, IC1841 should be
replaced with the one on previous main board. After
replacement, it should be required to perform the re-
adjustments following to the "Electrical Adjustments".
In this case, the lamp replace counter can be kept the
value as before.
-22-
Input Mode
Item No.
Data value
Version No.
35
TempC
Note :
This part of display
45.67
is available at the
service mode
Fan3Speed
No.80 - 123.
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

1 122 280 001 122 281 001 122 281 02

Table of Contents