Sanyo PLC-XU47 Service Manual page 13

Hide thumbs Also See for PLC-XU47:
Table of Contents

Advertisement

Optical Pats Disassemblies
c
Relay Lens-Out disassembly
1
A
Remove 2 screws
(M2.5x5) and pull the Relay Lens-Out ass'y upward.
2
B
Remove 2 screws
(M2x3) to take the Lens off from the holder.
Note:
There is no mounting direction of the lens.
v
Polarized Glass-In removal
1
Remove each screw (M2.5x5) and pull the Polarized Glass-In ass'y
upward.
2
Unhook the stoppers and take the glass off upward.
A
A
Fig.3-
1
* Should be places the glass as the
Fig.4-
1
-13-
Holder
Relay Lens-Out
Phase Sheet
Polarized Glass-In
Hooks
film attached side comes to the
prism side.
B
B
Fig.3-
2
Fig.4-
2

Advertisement