Before taking this procedure, remove Cabinet Top and Main board following to the "Mechanical
Disassemblies".
Disassembly requires a 2.0mm hex wrench and a screwdriver.
1.
PROJECTION LENS REMOVAL
A
1. Remove 2 screws
to slide the Lens Spacer and
B
remove 4 screws
to take the Projection Lens off.
2.
INTEGRATOR LENS REMOVAL
1. Remove 2 screws and pull the Integrator Lens Ass'y
upward.
2. Remove the Stopper and bend four hooks and then
take the Lens off from the Holder.
Note:
Should be placed the lens as the rugged surface side
of it comes to the holder side.
Projection Lens
Lens Holder
Integrator Lens Ass'y
-15-
B
A
A
Lens Spacer
Fig. 1
Integrator Lens
Stopper
Fig. 2