Optical Parts Disassemblies
,

Locations and Directions

When the optical parts in the optical unit mounting or assembling, the
parts must be mounted in the specified location and direction as
shown in figure below.
1
2
3
C
4
C
5
6
7
8
A
B
E
D
D
Key No. Description
1
2
3
4
5
6
7
8
9
10
11
12
The arrows in the figure indelicate the mount direction
of the part for the replacement. Check the number on
the arrows and mount each part according to its note;
A: The printed part no. comes to this side.
B: The printed part no. comes to the bottom side.
C: The printed part no. comes to this side.
D: The printed part no. comes to the top side and the
number can be read from the arrow direction.
E: The cutting corner comes to this side up.
12
11
10
9
-17-
Integrator lens (OUT)
Prism beam splitter (PBS)
Condenser lens (OUT)
Dichroic mirror (B)
Dichroic mirror (G)
Condenser lens
Relay lens (IN)
Mirror (R)
Condenser lens (R)
Condenser lens (B)
Mirror (B)
Optical filter (UV cut)
Fig.8