Download Print this page

Specifications - Aiphone IS-SS-CI Instruction Manual

Stainless steel flush mount door station with camera input

Advertisement

WIRING DIAGRAM:
IS-SS-CI
RELAY BOARD WIRING AND SETTINGS:
CCTV Input
CCTV Output
4-pin connector
*75Ω termination
for CCTV output
Relay 1 Output
N/O, COM, N/C
Relay 2 Output
N/O, COM, N/C
For door release
1.0 Amp contact
* Unit is shipped with the pin connector set to the ON
position. Change pin connector to the OFF position to
loop video from the CCTV output.

SPECIFICATIONS:

Terminations:
Relay rating:
Camera Input:
Operating Temp:
Wiring Distance:
Dimensions:
w/SBX-ISDVFRA:
Aiphone Corporation
1700 130th AVE NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
IS-MV
CAT-5e
OFF ON
NO
C
NC
NO
C
NC
Board on back of unit
See wiring below
**Connected to door
Configuration Switch
release output
See Settings to right
of door station
when shipped
***Option Input
Any N/O dry contact
can be used.
RJ45 jack for audio/video
Screw terminals for door release and relay outputs
24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board
Analog NTSC 1Vpp
14° ~ 140°F / -10° ~ 60°C
980' with Cat5e/6 cable
11-3/4" H x 7" W
11-11/16" H x 7-1/16" W x 2-13/16" D (top), 1-13/16" D (bottom)
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
For proper regulatory compliance, the drain wire should be disconnected at the power
supply end of the cable.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
TOLL FREE TECHNICAL SUPPORT:
CAT-5e
* Connect to the IS-CCU or IS-SCU and
program as a video door station, even if no
CCTV camera is connected.
Default Configuration when shipped
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers when the door release button of the master is pressed. Use this configuration if you need a larger
relay contact than the 0.5 Amp supplied from the door station.
Trigger Source
RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
Optional Configurations
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on communication and remains on during communication.
Trigger Source
RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
*** Relay 1 triggers on normal call and communication. Relay 1 remains on during communication. Relay 2 triggers
when option input is triggered and remains on during communication.
If using this configuration Relay 2 can not be used for door release. You must wire directly from the door station
relay output for door release and disconnect the Red/Bown wires that are currently wired to the door station relay.
Trigger Source
RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
Contact Technical Support if additional switch configurations
are required.
(800) 692-0200
E-MAIL: tech@aiphone.com
IS-CCU
*
RY1 Remains ON
RY2 Triggered?
During Talking?
YES
YES
NO
YES
YES
NO
YES
YES
NO
NO
N/A
YES**
RY1 Remains ON
RY2 Triggered?
During Talking?
YES
YES
NO
YES
YES
NO
YES
YES
YES
NO
N/A
NO
RY1 Remains ON
RY2 Triggered?
During Talking?
YES
YES
NO
YES
YES
YES
YES
YES
NO
NO
NO
N/A
IS-PU-UL
RY2 Remains ON
RY2 Requires
During Talking?
Reset?
N/A
NO
NO
N/A
NO
N/A
N/A
NO
RY2 Remains ON
RY2 Requires
During Talking?
Reset?
N/A
N/A
N/A
N/A
YES
NO
N/A
N/A
RY2 Remains ON
RY2 Requires
During Talking?
Reset?
N/A
N/A
YES
NO
N/A
N/A
N/A
N/A