COZY WOW253 Installation And Operating Instructions Manual page 20

Fan type direct vent through the wall gas heater
Table of Contents

Advertisement

TO REMOVE COMBUSTION TUBE ASSEMBLY FOR
INSPECTION, CLEANING AND REPLACEMENT
SERVICE MUST BE PERFORMED BY A
QUALIFIED SERVICE AGENCY.
A.)
Turn thermostat to "OFF" or lowest setting.
B.)
Allow heater to cool.
C.)
Turn off electric power to heater..
D.)
Turn gas supply valve to "OFF".
E.)
Disconnect gas supply line from gas valve.
F.)
From outside, remove six (6) screws
securing back of outer cabinet to air in
take and exhaust flanges. (See Figure 5).
G.)
From inside, gently slide combustion tube
assembly forward and out of outer
cabinet. (See Figure 6).
H.)
Disconnect air pressure switch tubing from draft
inducer. See Figure 18-A.
I.)
Remove draft inducer. (See Figure 18-A).
J.)
Disconnect ignition cable and pressure
switch tubing from top of burner box.
(See Figure 16).
K.)
Remove screws securing collection box and
burner box flange to liner top, bottom, left side,
right side and back. (See Figure 19).
L.)
Pull combustion tube assembly forward
and out of the liner. (See Figure 20).
M.)
You can now inspect, clean or replace
tubular heat exchanger as needed. NOTE: If
combustion tube assembly is being replaced,
you must keep and use collection and burner
box from assembly being replaced.
N.)
Carefully check integrity of all gaskets (replace
as needed), then reinstall combustion tube
assembly by reversing Steps L - A.
Follow lighting instructions to put heater
in operation.
FIGURE 19
For WOW253 / WOW254
IGNITOR
CABLE
IGNITOR
TRANSFORMER
CIRCUIT
BOARD
FIGURE 18-A
Page 20
PRESSURE
S W I T C H
TUBING
FIGURE 16
JUNCTION BOX
AIR INTAKE
CIRCULATING
BLOWER #1
LINER
PRESSURE
SWITCH
DRAFT INDUCER
(For WOW253 / WOW254)
FIGURE 20
BURNER
BOX

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wow254Wow403Wow404

Table of Contents