Fan type direct vent through the wall gas heater
Table of Contents

Advertisement

The State of Massachusetts requires that installation and service of a gas
appliance be performed by a plumber or gas fitter licensed in the
For bedroom window installation, the State of Massachusetts requires two or more operable
windows in the bedroom that are in compliance with 780CMR, Massachusetts Building Code.
Introduction......................................
Specifications and Dimensions.................

Safety Rules...................................

Location...................................................
Clearances.....................................
Installation..................................... 5 - 11

Lighting Instructions...........................

Proper Burner Flame.................................
Burner Orifice...........................................
THIS IS A GAS-FIRED, DRAFT INDUCED, POWER DEPENDENT, DIRECT VENT WALL FURNACE;
THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN
INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND
OPERATING INSTRUCTIONS, LOCAL CODES AND THE LATEST EDITION OF ANSI Z223.1/NFPA54
OR IN CANADA CSA B149.1. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING,
SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE
AGENCIES, THE GAS SUPPLIER OR THE MANUFACTURER.
Your Direct Vent Wall Furnace is shipped complete in one carton. This carton contains the furnace, installation
and operating instructions, ball-valve w/flex connector, wall thermostat, 20' wire, insulated staples, window
enclosure panels, caulking, weather stripping, and support brackets.
MODEL
INPUT
NO.
BTU/HR.
WOW253
20,000 BTU
WOW254
20,000 BTU
WOW403
40,000 BTU
WOW404
40,000 BTU
Commonwealth of Massachusetts.
CONTENTS
2
2
3
5
6
12
13
13
INTRODUCTION
SPECIFICATIONS AND DIMENSIONS
CABINET
WIDTH DEPTH
HEIGHT
14-3/8" 28-3/16" 17-1/8"
365 mm 716 mm 435 mm
14-3/8" 28-3/16" 17-1/8"
365 mm 716 mm 435 mm
25"
22"
17-1/8"
635 mm 559 mm 435 mm
25"
22"
17-1/8"
635 mm 559 mm 435 mm
Page 2
Gas Conversion.........................................

Wiring Diagram.................................

Sequence of Operation...............................
Maintenance Instructions.............................
Removing Main Burner..............................18 - 19
Removing Combustion Tube Assembly.......20 - 21

Trouble Shooting............................. 22 - 23

Parts Drawing.................................25 - 26
Parts List.......................................25 - 28
Warranty.........................................
GAS
TYPE
MAX. WALL
CONN. GAS
Thickness
3/8"
NAT.
3/8"
L.P.
3/8"
NAT.
3/8"
L.P.
MIN. WALL
Thickness
18"
4"
458 mm
102 mm
18"
4"
458 mm
102 mm
18"
4"
458 mm
102 mm
18"
4"
458 mm
102 mm
14
15
16
17
29