R E P A I R S
22
14
(196)
Pull pump inlet out of molded tube (21 / 201)
Remove upper pump holder (15 / 197) from pump (805 / 811).
To replace flow meter:
Remove cable connector from flow meter (22) if not already done.
Remove hoses and pull flow meter out of lower pump holder (14 / 196).
Assembly checkpoints
Check condition of pump holder (15 / 197): Replace a damaged pump holder.
Check that pump holder (15 / 197) fits correctly on pump (805 / 811).
Press in and turn new flow meter until it is locked on lower pump holder (14 / 196).
If the pump of a different manufacturer is used for replacement, additional parts of
the pump support etc. must be exchanged too (refer to annex of exploded drawings).
When inserting back the complete pump assembly with flow meter, check that the
latches of the lower pump holder (14 / 196) are in place correctly (clicking sound).