3) Press tip of red test probe onto
selected test point.
4) Press "measure" button and read off
displayed resistance.
The resistance must be lower than
0.3 Ohm.
Fill in measured value(s) in a test report.
9.9.4 What to do if the protective earth continuity test fails
•
Check/measure ground wire connections on:
•
terminal block for power cord (Maestria: 64, Gran Maestria: 145)
•
terminal screw on base (Maestria: 160, Gran Maestria: 141)
•
terminal screw on both thermoblocks (809, 810)
•
terminal screw on holder of brewing unit (78).
•
Check/measure ground connection on milk frother connector (refer to page 80 and
page 91 for wiring diagram). Replace milk frother connector if necessary.
•
Clean ground contact on milk frother. Measure resistance between ground contact
and jug of milk frother. Replace milk frother if necessary.
F U N C T I O N T E S T S
3.
4.
Maestria / Gran Maestria service manual
133