* Drain lines should not be installed directly to the sewer system. A vertical air gap of a minimum of 5
cm should be between the end of the drain hoses from the icemaker and the floor drain.
* To prevent a backflow into the storage bin, the outlet hose must be laid as shown.
GOOD
Downgrade
II. OPERATING INSTRUCTIONS
Do not step into the storage bin, or put your hands into the machine
compartment inside the storage bin. Children can get trapped inside, or the
icemaking mechanism may suddenly move, resulting in injury.
All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
This icemaker is designed to produce edible ice. To keep the icemaker hygienic:
* Wash your hands before removing ice. Use the plastic scoop provided (accessory).
* The storage bin is for ice use only. Do not store anything else in the bin nor use other electrical appliances in the bin.
* Clean the storage bin before use (see "III. 1. CLEANING").
* Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.
* Close the door after removing ice to prevent entrance of dirt, dust or insects into the storage bin.

1. START UP

The installer will normally commission the icemaker to start the automatic
icemaking process. To ensure continuous operation, make sure that:
* The water supply tap is on, and
* The icemaker is connected to the power supply.
To start the icemaking process, check the position of the operation switch on
the operation panel:
"OFF" position - Move it to the "ON" position.
"ON" position - Press the ice button.

2. SHUT DOWN

Push the stop button on the operation panel. The display will blink in the
"STOP" mode for 15 minutes during the drain control operation and will start
to illuminate constantly at the end of drain control.
BAD
Upgrade
CAUTION
NOTICE
HYGIENE
5
BAD
Floor
Operation Panel
Ice Button
Display
Stop Button
Maintenance Button
(service use only)
ENGLISH
5cm air gap
Drain
Operation Switch