Checking Temperature Sensors - Lochinvar ARMOR 151 - 801 Service Manual

Lochinvar water heater user manual
Table of Contents

Advertisement

The water heater temperature sensors (inlet water, outlet water, system water, and flue) are all resistance type devices. The
following tables show the correct values for the sensors at various temperatures. Use an ohmmeter to read the resistance of the
sensor at a known temperature. If the resistance of the sensor does not closely match its corresponding table, replace the sensor.
It is important to note that the flue and outlet water sensors have two temperature sensing devices in one housing. These devices
are designated as S1a/S1b, outlet sensor and S3a/S3b, flue sensor. Please reference the wiring diagram in the Armor Water Heater
Installation and Operation Manual for correct terminal location.
Table 3B -
50
68
86
104
122
140
Table 3C -
50
19,553
68
12,690
86
8,406
104
5,715
122
3,958
140
2,786
Table 3D -
50
40,030
68
25,030
86
16,090
104
10,610
122
7,166
140
4,943
26
Ω
18,780
12,263
8,194
5,592
3,893
2,760
158
2,004
176
1,464
194
1,084
212
816
158
3,478
176
2,492
194
1,816
212
1,344
158
176
194
212
--
--
50
40,030
68
25,030
86
16,090
104
10,610
122
7,166
140
4,943
50
258,500
68
125,500
86
80,220
104
52,590
122
35,270
140
24,160
Service Manual
Ω
1,990
1,458
1,084
817
--
--
158
3,478
176
2,492
194
1,816
212
1,344
158
16,870
176
12,000
194
8,674
212
6,369

Hide quick links: