Lochinvar AMP 200-9 Installation, Commissioning, User & Maintenance Instructions
Lochinvar AMP 200-9 Installation, Commissioning, User & Maintenance Instructions

Lochinvar AMP 200-9 Installation, Commissioning, User & Maintenance Instructions

Cavalier

Advertisement

Quick Links

LV 313545 | February 2020
Cavalier
Electric Water Heater
Installation, Commissioning,
User & Maintenance Instructions
Models:
Models:
AMP 200-9
AMP 300-9
AMP 200-18
AMP 300-18
AMP 200-36
AMP 300-36
AMP 300-54

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMP 200-9 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lochinvar AMP 200-9

  • Page 1 Cavalier Electric Water Heater Installation, Commissioning, User & Maintenance Instructions Models: Models: AMP 200-9 AMP 300-9 AMP 200-18 AMP 300-18 AMP 200-36 AMP 300-36 AMP 300-54 LV 313545 | February 2020...
  • Page 2 IMPORTANT INFORMATION These instructions must be read and understood before installing, commissioning, operating or maintaining the equipment.
  • Page 3: Preface

    Nothing from this publication may be copied, reproduced and/or published by means of Lochinvar accepts no liability for claims from third printing, photocopying or by whatsoever means, parties when: without the prior written approval of Lochinvar •...
  • Page 4: Contact Information

    as failure to comply with the guidance given will The purpose of this manual is to: • almost certainly result in an unsatisfactory describe the working principles and layout of installation: the water heater • • British Standards (BS), especially: explain the safety devices •...
  • Page 5: Table Of Contents

    Safety ............8 Caution Safety instructions ......8 Obey the caution instructions to prevent damage Instructions on the water heater ..9 of the water heater. Safety devices ........9 Environmental aspects ....11 Warning Obey the warning instructions to prevent danger Water heater ..........
  • Page 6: User Part

    Safety User Part Lochinvar cannot be held responsible for Introduction damages or injuries due to to: • Failing to follow the instructions provided in The AMP water heater stores and heats water this manual. • for sanitary purposes. Carelessness during use or maintenance of the water heater.
  • Page 7: Operation

    Caution 3.2.1.2 ON mode This water heater is not intended to be used by In the ON mode the water heater continuously children. Always supervise children, and make responds to the heat demand. The electric sure that they do not play with the water heater. heating elements are activated when there is a heat demand.
  • Page 8: Turn Off The Water Heater

    The tank of the water heater has to be Caution completely filled during operation. The tank at Preferably the temperature control knob, on each least must remain under mains water supply thermostat, should be set to 60°C. pressure at any time. Fresh cold water is immediately added when hot water is drawn from Harmful scaling and lime build-up will be higher the water heater.
  • Page 9: Instructions On The Water Heater

    The temperature exceeds 97°C. relief valve) The pressure exceeds 7 bar. 1- All water heaters have a T&P valve connection. Lochinvar recommends to always use a T&P valve. 6.3.1 Boil Dry Protection 6.3.1.1 Working principle The boil dry protection mechanism is a float...
  • Page 10 6.3.1.2 Exposure height contact is permanently closed and the safety mechanism does not work. This means that the The exposure height (3) of the reed contact is elements can come into operation without there very important to ensure the float switch works being sufficient water present in the device.
  • Page 11: Environmental Aspects

    Packaging 6.4.2 Disposal Lochinvar recommends unpacking the water Old end-of-life appliances contain materials that heater at or near its intended location. Remove need to be recycled. When you discard devices...
  • Page 12: Installation Diagram

    8.2.2 Maximum floor load refer to Warranty (see 11.6). If water specifications differ from the specifications in the Refer to the building construction engineer and table a water treatment specialist should be the general specifications in the appendices (see consulted. 11) to make sure that the maximum floor load is sufficient for the weight of the water heater.
  • Page 13: Water Connections

    Note Note Make sure that the circulation pump has the Use this installation diagram when you: correct capacity for the length and resistance of install the water connections (see 8.4) the circulation system. fill the water heater (see 8.6.1) drain the water heater (see 8.6.2) Install a circulation pump: 1.
  • Page 14: Commissioning

    7. Make sure that no water comes out of the expansion valve (15) or the T&P valve (3). If To determine the correct interval, Lochinvar water comes out: recommends doing a system check three months Examine if the water supply pressure is after installation.
  • Page 15: Performance Check

    Use a descaling agent if necessary remove lime 3. Open the T&P valve pressure relief and and dirt from the tank. Contact Lochinvar make sure that water flows from the outlet. Technical support for advice about which descaling agent to use. Lochinvar service...
  • Page 16: Troubleshooting

    Troubleshooting 10.1 General errors Fault Cause Solution Insufficient or Temperature set too low Set regulating thermostats higher. no hot water Overheat thermostat break the Press in reset button. circuit. Connector is not seated in stop Check the relevant parts. contact, mains switch is off or fuses are broken.
  • Page 17: Appendices

    Appendices 11.1 Technical Data Type Unit AMP200-9 AMP200-18 AMP200-36 Tank capacity ltr. Number of elements Power 380V-3F 15.2 30.3 Power 400V-3F 16.8 33.6 Power 414V-3F 18.0 36.0 Heating time up to 60°C * min. 83/78 42/39 21/19 (400 / 414V) Heating time up to 40°C * min.
  • Page 18: Dimensions

    11.2 Dimensions Description AMP200 AMP300 Height hot water connection 1460 1580 Height of upper side of device 1420 1540 Diameter of water heater Depth Height of drain valve Height cold water supply Height T&P connection 1230 1335 1¼”-14NPT 1¼”-14NPT Cold water connection 1¼”-14NPT 1¼”-14NPT Hot water connection...
  • Page 19: Ecodesign Data

    11.3 EcoDesign Data Description Unit AMP200-9 AMP200-18 AMP200-36 Load Profile Energy Efficiency Class Water Heating Efficiency 38.0 38.0 38.0 Daily Electricity Consumption 20.161 20.161 20.161 Daily Fuel Consumption kWh GCV 0.000 0.000 0.000 ∞ Mixed Water 40°C (V40) ltr. Additional Load Profile Energy Efficiency Daily Electricity Consumption Daily Fuel Consumption...
  • Page 20: Electrical Diagram

    11.4 Electrical diagram Fig. 3 phases/3 elements (9 kW) A = Network connection B = Fuses C = Relay D = Fuse E = Transformer = Safety relay G = Float switch H = Overheat thermostat K = Regulation thermostat = Electrical heating element X1 = Terminal block = Black...
  • Page 21 Fig. 3 phases/6 elements (18 and 36 kW) A = Network connection B = Fuses C = Relay D = Fuse E = Transformer = Safety relay G = Float switch H = Overheat thermostat K = Regulation thermostat = Electrical heating element X1 = Terminal block = Black = Red...
  • Page 22 Fig. 3 phases /9 elements (54 kW) A = Network connection B = Fuses C = Relay D = Fuse E = Transformer = Safety relay G = Float switch H = Overheat thermostat K = Regulation thermostat = Electrical heating element X1 = Terminal block = Black = Red...
  • Page 23: Declaration Of Conformity

    11.5 Declaration of conformity 0313545_AMP_UKUK_V2.0, 03-02-2020...
  • Page 24: Warranty

    Lochinvar Ltd, following verification, and at the sole discretion of Lochinvar Ltd, the enamel-lined steel tank proves to be leaking due to rust or corrosion occurring on the water side, then Lochinvar Ltd shall offer to replace the defective water heater with an entirely new water heater of equivalent size and quality The warranty period given on the replacement water heater shall be equal to the remaining warranty period of the original water heater that was supplied.
  • Page 25 Lochinvar Ltd. Inspection of the water heater as referred to in articles 1 and 2 shall take place in one of the laboratories of Lochinvar Ltd. Article 7: Obligations of Lochinvar Ltd.
  • Page 28 Lochinvar Ltd reserves the right to change 7 Lombard Way, The MXL Centre, Banbury, Oxon, OX16 4TJ specifications without prior notice Tel: +44(0) 1295 269 981, Fax:+44(0) 1295 271 640, Email: info@lochinvar.ltd.uk www.lochinvar.ltd.uk...