  • Page 1       STAFF TRAINING MANUAL Blood Pressure Monitor  Model: BPM1KTL                BPM1KTL Training Manual   ...
  • Page 2   Q. Does taking a measurement hurt?     Please review and refer to this training manual giving you all  A. No, although some slight discomfort may be felt as the cuff  inflates.  the information behind Kinetik Blood Pressure Monitor, the    technology it uses, and who is behind it. This is so all customer  Q. Are they any risks from over‐use?  questions can be answered.    A. Blood pressure should be monitored at least once a day. It  What is the BPM1KTL?  is recommended to wait at least 60 minutes between  readings.   The BPM1KTL is an electronic blood pressure monitor (also    known as a sphygmomanometer), a medical device that is  Q. What are the advantages of the BPM1KTL?  used to measure arterial blood pressure. The BPM1KTL    comprises of a main unit that houses the battery, control  A. It is very accurate, premium blood pressure monitor that is  panel and LCD, this connects to the user through a cuff that is  capable of measuring and classifying blood pressure in a  wrapped around the upper arm. The BPM1KTL is the first  simple and reliable way. It is also able to notify the user if  ever ‘Traffic Light’ type Blood Pressure Monitor to be tested  irregular heartbeats are detected during a measurement.    and approved by the British Hypertension Society.      Q. Does the Kinetik BPM1KTL run off the mains or from  What is Hypertension?  batteries?    is a chronic medical  Hypertension (or High Blood Pressure) A. It runs on batteries (4 x AAA). ...
  • Page 3: Frequently Asked Questions

    Treating Hypertension  Frequently asked Questions  Dietary and lifestyle changes can improve blood pressure  Q. Why should I measure my blood pressure?  control & decrease the risk of associated health    complications and this must always be considered as the first   A. High blood pressure is a leading cause of heart attack and  step in treating hypertension. However, drug treatment may  strokes. High blood pressure has no obvious symptoms and  can only be detected by using a blood pressure monitor.  prove necessary in patients for whom lifestyle changes prove    ineffective or insufficient.   Q. Is the BPM1KTL clinically approved?    BPM1KTL Blood Pressure Monitor main messaging claims:   A. Yes. It has Medical CE for efficacy and safety under the   European Medical Device Directive. It has also been approved  Clinically tested and approved by the British  by the British Hypertension Society.  Hypertension Society.      Q. What is the BPM1KTL and how does it work?   Provides blood pressure classification via a user    friendly ‘Traffic Light’ system.  A. It is a non invasive digital blood pressure monitor that    quickly and accurately measures arterial blood pressure   through an inflatable cuff that is wrapped around the upper  Able to detect irregular heartbeats and notify the  arm. user accordingly.     ...
  • Page 4 Who do we target?   Who is behind the brand?   The Kinetik Blood Pressure Monitor is suitable for adults and  The Kinetik BPM1KTL Blood Pressure Monitor is made by  Harvard Medical Devices, the UK's leading supplier of home  children. It is NOT recommended for infants.   use medical products and electrical home health devices with  over 2 million units sold. Harvard Medical Devices has  The Kinetik BPM1KTL Blood Pressure Monitor:   ISO13485, ISO9001 & Standards Council of Canada    accreditation. Harvard Medical Devices is also registered with    the US Food & Drug Administration and is a member of the    British Standards Institution.      This Kinetik Blood Pressure Monitor has been developed    according to the specifications and standards detailed in the    European Medical Device Directive 93/42/EEC and approved  by the British Hypertension Society.         Product Specification    British Hypertension Society Approval.   ‘Traffic Light’ Blood Pressure Classification System    Irregular Heartbeat Detection System  2 x 30 User Memory.    Measures Blood Pressure and Heart Rate.  Accurate to +/‐3mmHg  Fully Automatic.   ...
  • Page 5     Irregular Heart Beat (Cardiac Arrhythmia) Detection    Blood Pressure Classification:       The BPM1KTL is designed to detect Premature Ventricular  Blood pressure is classified based on the systolic and diastolic  Contractions, also known as a Premature Ventricular Complex  blood pressures measured in millimeters of mercury (mmHg).  (or complexes), Ventricular Premature Contractions (or  Systolic blood pressure is the blood pressure in vessels during  complex or complexes), Ventricular Premature Beats, or  a heartbeat and is the higher number. Diastolic blood  Extrasystoles. It is not designed to detect Atrial Fibrillation or  pressure is the pressure between heartbeats and is the lower  Atrial Premature Beats. If an irregular heart beat is detected  number. These two numbers are given together i.e. “120 over  during measurement, an indicator will be displayed and the  80” to indicate a blood pressure value.  measurement should be taken again after a short rest.    How to use the BPM1KTL Blood Pressure Monitor:   IMPORTANT:     The cuff must be wrapped 1‐2cm above the elbow joint with  Users should refrain from eating, drinking, smoking or  the rubber tube running down the centre of the arm.  exercise for 30 minutes in order to obtain accurate results.  The user should rest for 5 minutes before taking a reading  and should not move or talk while the reading is being taken.                                                          ...
  • Page 6 (mild)  Amber  automatically inflate and measure the blood pressure  Grade 2 Hypertension  160‐179 100‐109 Red  reading.  (moderate)    Grade 3 Hypertension  ≥180 ≥110 Flashing Red    (severe)  Traffic Light System    * Low blood pressure, or hypotension, occurs when blood pressure  The backlight of the BPM1KTL will change colour according to  during and after each heartbeat is much lower than usual. This  the measured result. The different backlight colours  means the heart, brain, and other parts of the body do not get  correspond to blood pressure classifications as defined by the  enough blood. Symptoms may include blurry vision, confusion,  dizziness, fainting, light‐headedness, sleepiness & weakness.  British Hypertension Society. The BPM1KTL Traffic Light  However, blood pressure that is borderline low for one person may  System presents your blood pressure classification via a  be normal for another. Consequently, hypotension in a healthy  simple and easy to understand user interface.  person that does not cause any problems usually doesn't require    treatment. If in doubt, seek advice from your physician or    healthcare professional.       ...