Content Specification Support Return Policy / Warning and safety Introduction notices Parts EMC Table 17-19 Setting up your Blood Pressure Monitor Frequently Asked Questions 20-21 Battery Loading Connecting the Cuff Abnormality & Troubleshooting Putting on the Cuff Maintenance Using your Blood Pressure Monitor 7-14 Blood Pressure Record Table Your first test...
We promise to respond to all queries and will ensure to resolve any issue you may be having. You can reach us by… Phone: +44 1483 937969 Live Chat: Simply visit www.kinetikwellbeing.com and send us a message. Email: customercare@kinetikwellbeing.com Post: Kinetik Medical Devices Limited Unit 3, Perrywood Business Park, Honeycrock Lane, Salfords, Redhill. RH1 5DZ...
Introduction Thank you for buying your Kinetik Fully Automatic Blood Pressure Monitor. Whether you have already been diagnosed with high blood pressure or want to track any changes to your blood pressure, you have taken the first step to quick, easy and accurate measurement that will keep you and, if necessary, your doctor informed.
Setting up your Blood Pressure Monitor Loading the Batteries a. Open the battery cover at the back of the monitor. b. Insert three “AA” batteries, observing correct polarity. c. Close the battery cover. Do not mix old and new batteries or different types of batteries. Do not use rechargeable batteries. Only batteries of the same or equivalent type as recommended are to be used.
Setting up your Blood Pressure Monitor Putting on the Cuff a. Place the cuff 1~2cm above the elbow joint. b. Place hand on a flat surface with the palm facing up and with the rubber tube running down the center of the arm. Measuring can be done on light clothing such as a shirt or blouse.
Using your Blood Pressure Monitor Your first test The British Hypertension Society (BHS) recommends that for your first test, you test both your arms. (Note: Ensure you do not suffer from any medical conditions which will prevent you from having your blood pressure measured in both arms). This will determine which arm should be used for future measurements.
Using your Blood Pressure Monitor Setting the time and date Once the batteries are inserted and the battery cover is put back into place, the display will flash the year 2015 in the bottom left hand corner. To adjust the Year press the MEM button repeatedly until correct (pressing and holding the MEM button will advance the year rapidly).
Using your Blood Pressure Monitor Measuring Process a. This monitor is uses Measure While Inflate technology. This means that the measurement is made as the cuff inflates, rather than fully inflating first then measuring during the deflation stage. As the cuff inflates the display will show the following: Measurement Progress Indicator Cuff Pressure in mmHg Pulse Detection*...
Using your Blood Pressure Monitor What the results mean a. The LCD screen will automatically display the systolic and diastolic pressure reading in mmHg and the pulse rate in pulse/min after each measurement. b. Record date, time, systolic reading, diastolic reading and pulse rate on your record card which you will find in the pack (including anything that may have influenced your blood pressure reading e.g.
Using your Blood Pressure Monitor Re-measuring If you want to measure again, just press the START/STOP button twice. Leave at least three minutes between measurements to allow blood circulation to the arm to return to normal. Do not measure your blood pressure too many times in one session as it may cause discomfort in the arm.
Using your Blood Pressure Monitor Memory The memory can store 90 sets of measurements and these results will be automatically stored after each reading. To check the memory, press the MEM button (either just after a measurement has been taken or while the unit is off).
Interpretation of Blood Pressure (BP) Results Category of Blood Systolic BP Diastolic BP Advice on Results Pressure (mmHg) (mmHg) Hypotension <100 <60 Practice a healthy lifestyle. Consult your doctor only if suffering symptoms of low BP (eg. fainting) Ideal <120 <80 Practice a healthy lifestyle.
Additional Information on Blood Pressure Your heart is just like a pump which works all the time to make the blood flow through all blood vessels. Blood pressure measures the force on the wall of the blood vessels caused by the pressure of the blood.
Specification (1) Model: BPx1A (12) Automatic power off: To be automatically cut off (2) Digital display system after 2minutes of not being use to save energy. (3) Measuring method: Oscillometric method (13) Battery life: Approx.3 months with 3 times usage per day...
Product may be returned if faulty, please contact the Retailer or Kinetik directly if you’re experiencing issues with your product. This does not affect your statutory rights. Please note the retailer’s own return policy may still be valid, contact the retailer for more information.
EMC Table Guidance and manufacture’s declaration Guidance and manufacture’s declaration – electromagnetic emission The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer of the user of the Digital Blood Pressure Monitor should assure that it is used in such an environment. Compliance Emission test Electromagnetic environment –...
Page 19
EMC Table IEC 60601 test Compliance Immunity test Electromagnetic environment - guidance level level Portable and mobile RF communications equipment should be used no closer to any part of the Digital Blood Pressure Monitor, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
EMC Table Recommended separation distances between portable and mobile RF communications equipment and the Digital Blood Pressure Monitor. The Digital Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Digital Blood Pressure Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Digital Blood Pressure Monitor as recommended below, according to the maximum output power of the communications equipment.
Frequently Asked Questions What is the difference between systolic and diastolic pressure? Your heart is just like a pump which works all the time to make the blood flow through all blood vessels. Blood pressure measures the force on the wall of the blood vessels caused by the pressure of the blood. Systolic pressure is the pressure of the blood when your heart beats to pump blood out.
Frequently Asked Questions Do I need to test at the same time, every time? We recommend that measurements are taken at the same time, under the same conditions and in the same position each time because of the way your blood pressure constantly fluctuates depending on the time of day. This will help you to keep a more accurate record over time and reduce any possible variances to your readings.
Abnormality & Troubleshooting Error Indicators The following symbol will appear on the display when measuring abnormally. Symbol Cause Correction Cuff not fitted correctly or air leakage Wrap the cuff correctly and tightly ensuring the connection detected. between the air plug and the unit is good. Do not move your arm or body, refrain from talking.
Blood Pressure Record Table Please log the date, time and your SYS (systolic) and DIA (Diastolic) blood pressure levels. We recommend you share this information with your Doctor...