Troubleshooting - Lochinvar SOLUTION 260000 Installation & Service Manual

45,000 - 260,000 btu/hr
Table of Contents

Advertisement

8

Troubleshooting

Troubleshooting Guide: M9 Solution Boilers
Step 1:
Is the spark
ignitor sparking?
Yes
Is the pilot
Step 2:
staying on?
Yes
Step 3:
Is the gas valve
getting 24 VAC
to the MV
terminal?
Yes
No
Check
voltage to
and from the
transformer.
No
Check incoming
120 VAC.
No
Check the pilot
tube for gas.
No
Check draft.
Is there 24 VAC (purple
wire) on the 4-pin
connector plug on the
temperature controller?
Replace the
No
ignition
module.
Check gas pressure
and make sure gas
valve knob is on.
Check 24 VAC at R and W on
the terminal strip.
Yes
Check each of the
following for an open:
-white and purple wire on
the LWCO plug
-rollout switch
-manual reset high limit
-spill switch
If any of these devices are
open, press the reset
button.
Installation & Service Manual
Check continuity on the spark
cable. Check for 24 VAC on
the 24v terminal (gray wire)
on the ignition module.
No
Replace ignition
module.
Yes
No
Check for an open
sensor. If no open
sensor, make sure
there's a call for
heat. If call for heat
is present, replace
temperature control.
Yes
No
Is there 24 VAC (tan
wire) on the 4-pin
connector plug on
the temperature
controller?
Yes
Check each of the
following for an open:
- X and B on the
terminal strip
-purple and gray wires
on the vent damper
plug
-V and P on the
terminal strip
-auto reset high limit
49