Troubleshooting; The Power Source Does Not Start, Control Panel Off - Cebora POWER ROD 1350 Service Manual

Mma and tig welding system
Table of Contents

Advertisement

CEBORA S.p.A.

3.3 - Troubleshooting.

ANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIED
BEFORE REMOVING THE PROTECTIVE GUARDS AND ACCESSING INTERNAL
PARTS, DISCONNECT THE POWER SOURCE FROM THE MAINS AND WAIT FOR THE
INTERNAL CAPACITORS TO DISCHARGE (3 MINUTES).
Items in boldface describe problems that may occur on the machine (symptoms).
Operations preceded by this symbol refer to situations the operator must determine (causes).
q
♦ Operations preceded by this symbol refer to actions the operator must perform in order to
solve the problems (solutions).

3.3.1 - The power source does not start, control panel off.

MAINS SUITABILITY TEST.
No voltage for mains protection.
q
♦ Eliminate any short-circuits on the connections between power cable, switch (5)
and power board (15).
♦ Make sure that the VAC and 220 mains input terminals on power board (15) are
not short-circuited between them or towards earth.
♦ Mains not suitable to power the power source (ex.: insufficient installed power).
MAINS CONNECTION TEST.
Power board (15), VAC and 220 terminals = 230 Vac, with switch (5) closed.
q
♦ Check power cable and plug and replace if necessary.
♦ Check switch (5), and replace if defective.
♦ Check the mains voltage conditions.
♦ Replace the power board (15).
3.302.050
WARNINGS
PERSONNEL.
NOTE
Correct?
NO
YES
Correct?
YES
NO
7
22/12/00