Minimum Clearance Requirements For Non-Combustible Surroundings - Hatco GR Series Installation And Operating Manual

Infrared strip heaters
Hide thumbs Also See for GR Series:
Table of Contents

Advertisement

Available languages

Available languages

CONTENTS

Minimum Clearance Requirements for Non-Combustible Surroundings

Corded Units with Built-In Switches
Models
(A)
GRa and
253 mm
GRaL
(10")
GRaH and
279 mm
GRaHL
(11")
Hardwired Units with Built-In Switches
Models
(A)
GRa and
203 mm
GRaL
(8")
GRaH and
GRaHL
253 mm
with Infinite
(10")
Heat Control or
Indicator Light
GRaH and
GRaHL
203 mm
with ON/OFF
(8")
Toggle Switch
Hardwired Units with Remote Switches
Models
(A)
GRa and
203 mm
GRaL
(8")
203 mm
GRaH and
GRaHL
(8")
(B)*
(C)
---
76 mm
---
(3")
---
76 mm
---
(3")
(B)*
(C)
---
25 mm
---
(1")
---
25 mm
---
(1")
---
25 mm
---
(1")
(B)*
(C)
0 mm
0 mm
(0")
(0")
0 mm
0 mm
(0")
(0")
Pass-Through Shelf
Counter
Figure 12. Non-Combustible Clearance Requirements
Dual Units with Built-In Switches
Models
GRa-XXD
GRaH-XXD
253 mm
(10")
GRaL-XXD
GRaHL-XXD
Dual Units with Remote Switches
Models
GRa-XXD
GRaH-XXD
203 mm
GRaL-XXD
GRaHL-XXD
* Must be a pass-through application, not allowed with back
wall installation.
20
C
B
A
(A)
(B)*
---
---
(A)
(B)*
76 mm
(8")
(3")
Form No. GRCEM1-0611
(C)
25 mm
(1")
(C)
0 mm
(0")

Advertisement

Table of Contents
loading

Table of Contents