(7) Inrush Current Limiting Circuit
Inserter Cover Open/close Switch
This circuit limits an inrush current flowing into the regeneration capac-
itor included in the motor drive system to a certain value or less. The
circuit consists of the PTC thermistor (PTH2) that limits a current and
the FET (Q11) that allows a steady current flowing.
When the inserter cover open/close switch is closed, the cathode volt-
age of ZD1 starts rising to the zener voltage according to the time con-
stant of R55 and C46. During the rise of the cathode voltage, Q11 is off
because no base current to Q10 keeps Q10 off, and then a current
flows to PTH2 to charge the regeneration capacitor.
(8) Operator Panel Drive Circuit
Operator Panel
This circuit includes the input circuits of the switches on the operator
panel and the drive circuits of the LEDs.
The circuits connected to CN15-Pin1, 2, 3 are the input circuits of the
switches on the operator panel. The input signal from the switch goes
"L" when the switch is on, "H" when off.
The circuits connected to CN15-Pin4,6-11 are the drive circuits of the
LEDs on the operator panel. The LED lights when the signal is "H",
does not light when "L".
After the regeneration capacitor is fully charged, and the cathode volt-
age of ZD1 reaches over the zener voltage according to the time con-
stant of R55 and C46, Q11 is turned on because the base current from
ZD1 to Q10 turns Q10 on. And then the current flows to Q11 instead of
PTH2 to release the current limitation. The circuit consisting of PTH1
and D3 is intended to eliminate the electric charge accumulated in C46
immediately to limit an inrush current generated by momentary open-
ing and shutting of the cover.