9.7.2 ActionSelector
Select Action 1 or Action 2.
9.7.3 ActionGroupMask
Set the mask value for grouping Action 1 operation.
9.7.4 ActionGroupKey
Set the key (value) to operate Action 1.
10. Operation modes
This camera can operate in the following functions.
1. Continuous
2. Timed (Smearless OFF, EPS)
3. Timed (Smearless ON)
4. Trigger Width (PWC)
The followings are JAI Custom modes.
5. Pre-Dump (RCT)
6. Particle Image Velocimetry (PIV)
7. Sequential trigger
8. Delayed Readout trigger
9. ROI readout
10. OB transfer readout
10.1. Continuous mode (Free run)
For applications not requiring asynchronous external triggering, this mode should be
used. In this mode it is possible to use a lens with a video controlled iris. As for the
timing, please refer to chapter 7.7 "Video output timing". In continuous mode,
exposure time can be controlled by the frame rate or by the electronic shutter. The
following examples describe the GenICam settings used to configure the camera for
continuous operation.
To use this mode:
Acquisition mode
Trigger selector
Trigger mode
Exposure mode
Note: If ExposureMode is set to Timed, the exposure can be controlled.
or
Acquisition mode
Trigger selector
Trigger mode
Exposure mode
AM-800GE / AB-800GE
: Continuous
: Frame Start
: OFF
: OFF or Timed
: Continuous
: Frame Start
: ON
: OFF
- 55 -