Operation DN9340:
Select dynamic equalisation by pressing the DYNAMIC key.
The display for the parametric equaliser is similar to the home page, showing the frequency response of the
T-DEQ
two
dynamic EQ sections. Note, however, that for each of the two sections there are two different
curves drawn. These correspond to the response curve at high signal level and low signal level respectively.
For more details on dynamic equalisation see the application notes later
Soft Key Functions
o
o
o
T-DEQ
Dynamic equalisation
this switches the controls between the two dynamic EQ sections
Default page shows frequency and Q/slope for this section.
Each of the sections can be used over the whole frequency range from 20Hz to 20kHz,
and has fully parametric control over Q. In addition, each section can be selected to be
a high or low shelf, with 6dB/octave or 12dB/octave slopes. This is selected by turning
the Q knob beyond its maximum value of 20.
Lo Threshold / Level page
This page contains the settings for the low threshold (the signal level that we want to
call "quiet") and the amount of cut or boost that we want at that "quiet" signal level.
Hi Threshold / Level page
This page contains the settings for the high threshold (the signal level that we want to
call "loud") and the amount of cut or boost that we want at that "loud" signal level.
on page 31