The large red alphanumeric displays can be used to
show electronic scribble-strip information, Last
Memory Recalled, and Communications Mode.
Display mode indicator (blue) for Section 2. When lit
this indicates that the large red displays are now
s h o w i n g L a s t M e m o r y R e c a l l e d a n d
Communications Mode. When not lit, the displays
are showing electronic scribble-strip names. In this
case the left-hand three characters show the name of
Channel A and the right-hand three the name of
Channel B.
SETUP key. Press and hold to enter SETUP menu. A
momentary press toggles between the electronic
scribble-strip displays and display of Last Memory
R e c a l l e d a n d C o m m u n i c a t i o n s M o d e .
Communications Mode is not editable when display is
accessed this way.
UP and DOWN keys for Section 1. Used to select
communications channel (address) for remote
control and also contact closure mode. Active only
when in SETUP menu.
Display mode indicator (blue) for Section 1. When lit
this indicates that the large red displays are now
s h o w i n g L a s t M e m o r y R e c a l l e d a n d
Communications Mode. When not lit, the displays
are showing electronic scribble-strip names. In this
case the left-hand three characters show the name of
Channel A and the right-hand three the name of
Channel B.
Remote Control Active indicator (green) for Channel
1A. This shows that that the master unit is currently
controlling this channel by remote control. Often
referred to as the "me" light. (repeat for 1B/2A/2B).
DN9344
Power on indicator.
Power switch.
Section 2 output metering incorporating multi-point
clip indication.
T-DEQ
Section 2
Section 2 input metering incorporating multi-point
clip indication.
UP and DOWN keys for Section 2. Used to select
communications channel (address) for remote control
and also contact closure mode. Active only when in
SETUP menu.
Communications traffic indicators. These indicate
when there is activity on any of the external
interfaces. Transmit and receive data are shown for
front panel (RS-232) and rear panel (RS-485) data,
and also the contact closure (RELAY) input.
PC port connector. Use with the supplied cable to
install software updates or to control the unit from an
external computer.
Section 1 output metering incorporating multi-point
clip indication.
T-DEQ
Section 1
Section 1 input metering incorporating multi-point
clip indication.
Scribble-strip areas to allow easy labelling of the unit.
Use only chinagraph pencils to avoid permanently
marking the unit. Remove chinagraph markings by
wiping with a soft cloth. Do not use solvents as these
may damage the surface.
6
abc
l
dynamic EQ metering.