Bunn ITCB-DV Technical Training Manual page 18

Table of Contents

Advertisement

ENABLE ADS ?
NO
DONE
YES
ENABLE SANITATION
NO
DONE
YES
ENABL ENERGYSAVR
NO
YES
DONE
ENABLE FRESH TIMER
DONE
YES
NO
XX
REFILL
(-)
DONE
(+)
SPRAY OZ/M: XX.X
(-)
DONE
(+)
BYPS OZ/M: XX.X
( - )
DONE
( + )
DILUTE OZ/M: XX.X
(-)
DONE
(+)
CALIBRATE FLOW?
NO
YES
BREW COUNTERS?
NO
YES
SET RECIPES TEMPS
NO
YES
ENTER ASSET #
NO
YES
18
ITCB-DV HV Training
This function allows the operator to choose whether or not to display an advertising mes-
sage. An ad can be saved to the brewer by either writing the ad using the programming
commands, or by entering the ad into the brewer using an Ad Card. This message will
be displayed when the brewer is not in use.
This function allows the operator to enable the sanitation function and set the time be-
fore a cleaning alert will be displayed.
This function allows the operator to enable the Energy Savings mode function and set
the idle time. Once the set idle time has expired, the operator can choose to have the
heaters either turn off, or reduce the tank holding temp to 140° F (60° C).
This function allows the operator to enable the Freshness Alert and set the expiration
time. The fresh time is the amount of time the product is allowed to sit in the server/dis-
penser before a batch is considered expired.
This function allows the operator to adjust the sensitivity of the refill circuit. This is main-
XXX
ly a troubleshooting feature. Water in different geographical locations can have different
conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to
operate under various water conditions.
This function allows the operator to view or enter the actual flow rate coming out of the
sprayhead. This is Not used to control the actual flow rate, but to tell the internal proces-
sor how fast the water is flowing.
This function allows the operator to view or enter the actual flow rate coming out of the
bypass valve. This is Not used to control the actual flow rate, but to tell the internal
processor how fast the water is flowing.
This function allows the operator to view or to enter the actual flow rate coming out of
the dilution nozzle. This is not used to control the actual flow rate, but to tell the internal
processor how fast the water is flowing.
This function allows the operator to test and enter the actual flow rate of the
sprayhead(s) and the bypass/dilution for each side of the brewer by dispensing each
separately for one minute. The volumes are then entered into the brewer.
This function allows the operator to track the total number of brew cycles completed, as
well as the number of batches brewed using each of the brew buttons. There are (up to)
three resettable counters, and one life counter that is not resettable.
This function allows the operator to set separate temperatures for each selected recipe.
This function allows the operator to enter the machine's asset number. This can be use-
ful for tracking the usage or service of an individual machine within a group.