Programming Lockout; Level 1 Programming; Level 2 Programming - Bunn ITCB-DV Technical Training Manual

Table of Contents

Advertisement

Setup and Programming

Programming Lockout

If the programming cannot be access then the programming lockout
switch is in the Lock position. The switch is located on the control
board. Remove the top panel, locate the switch and place it into the
Unlock position.

Level 1 Programming

Press the hidden switch for one second to access.
BREW LOCKOUT ?
ON
DONE
OFF

Level 2 Programming

Press and hold the hidden switch for 5 seconds
Set Language?
NO
YES
UNITS
Metric
ENG
DONE
REVIEW RECIPES ?
NO
YES
ASSIGN RECIPE ?
NO
YES
SET NEW RECIPE ?
NO
YES
MASTER TEMP 200
(-)
DONE
(+)
READY DEGREE 5
(-)
DONE
(+)
This function allows the operator to prevent or allow brewing if the water temperature is
less than the Set Ready temperature.
This function allows the operator to select the language used for the display.
This function allows the operator to select if numeric settings are displayed in English or
Metric units.
This function allows the operator to view the brew settings for various coffee recipes
stored into the brewer. It also allows the operator to modify any of the brew settings for a
particular recipe stored in the brewer.
This function allows the operator to assign a recipe to (or disable) each of the 3 brew
switches (A, B, C). Any saved recipes listed under "Review Recipes" can be assigned to
a brew switch. Only one recipe per brew switch is allowed.
This function allows the operator to set Brew Volumes, Bypass %, Pulse Brew/Preinfu-
sion Times and Drip Out Times for each coffee name stored in the grinder's memory.
This function allows the operator to adjust the brew water temperature in the tank. This
O
also sets the hot water faucet dispense temperature. (Range 150-207°F)
This function allows the operator to set the minimum temperature allowable to start a
O
brew cycle. The range can be from 2° to 20° F below the set temperature. The water
must be at the Ready temperature or higher for the display to indicate Ready To Brew. If
brew lockout is enabled, the brewing process won't start below this Ready temperature.
MEMORY
PROGRAMMING
LOCKOUT SWITCH
P3048