Unpacking; Installation Of Appliance; Fireplace Size; Fireplace Flue Pull - Baxi 939 Installation And Owner's Manual

Open decorative gas fire
Hide thumbs Also See for 939:
Table of Contents

Advertisement

Contents:
1
Burner assembly.
1
Nut & olive for 8mm inlet pipe.
4
Screws.
4
Plastic screw plugs.
1
Fuel bed matrix support plate.
2
Self tapping screws.
1
Inlet 'T' connector / elbow.
1
Ceramic fuel effect pack.
1
Burner tray trim (Not fitted to Anthem or Quattro models).
For models supplied with a firefront
1
Firefront and ash pan cover (Where applicable).
Carefully remove the contents. Take special care in handling the ceramic fuel effect
pieces. Check that all the listed parts are present and in good condition.
INSTALLATION

6.1 Fireplace size.

The fireplace must comply with the requirements described in section 4.

6.2 Fireplace flue pull.

Visually inspect the flue for any obstruction, and that a smooth transition from the
fireplace opening into the flue is available. Close all doors and windows in the room in
which the appliance is to be installed. After confirming with a match that smoke is
drawn into the flue, light a 13 gram smoke pellet and check that there is a definite
flow through the flue. Verify outside that the smoke exits from one terminal only and
that the termination is suitable. Observe, where possible, upstairs rooms and loft
spaces for signs of escaping smoke indicating a defective flue. If there is not a
definite flow warm the flue for a few minutes and repeat the smoke pellet test. If there
is still no definite flow the flue may need remedial work – Do not fit the appliance
until there is a definite flow through the flue.