This appliance is for use with natural gas (g20). when converted using conversion kit no. 0595241 this appliance is for use with propane gas (g31).

Advertisement

Quick Links

INSTALLER GUIDE

THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION
KIT NO. 0595241 THIS APPLIANCE IS FOR USE WITH PROPANE GAS (G31).
THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM (GB) AND THE
We trust that this guide gives sufficient details to enable this appliance to be installed and maintained
satisfactorily. However, if further information is required, our Baxi Fires Division Technical Helpline will be
Please telephone 08706 061 065 (National call rates apply in the United Kingdom). In the Republic of
INSTALLER: Please leave this guide with the owner
© Baxi Heating U.K. Ltd.
Page 1
Baxi Fires Division fires are CE Approved and designed to meet the appropriate British Standards and Safety
Quality and Excellence at the heart of every Baxi Fires Division fire.
All Baxi Fires Division fires are manufactured to the highest standards of quality and excellence and are
manufactured under a BS EN ISO 9001 quality system accepted by the British Standards Institute.
http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I...
BAXI FIRES DIVISION
Model
949
(GC No. 32-032-66)
OPEN DECORATIVE
GAS FIRE
REPUBLIC OF IRELAND (IE).
pleased to help.
Ireland telephone 0044 8706 061 065.
BAXI • VALOR • WONDERFIRE
Safety First.
Marks.
Page 1 of 25
5112260/01
20/08/2012

Advertisement

Table of Contents
loading

Summary of Contents for Baxi 949

  • Page 1: Installer Guide

    © Baxi Heating U.K. Ltd. Page 1 Safety First. Baxi Fires Division fires are CE Approved and designed to meet the appropriate British Standards and Safety Marks. Quality and Excellence at the heart of every Baxi Fires Division fire. All Baxi Fires Division fires are manufactured to the highest standards of quality and excellence and are manufactured under a BS EN ISO 9001 quality system accepted by the British Standards Institute.
  • Page 2: Table Of Contents

    Page 2 of 25 The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Baxi Fires Division is a CORGI registered company. All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet or floor of combustible material.
  • Page 3: Safety

    Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.This appliance does not contain any component manufactured from http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 4: General Installation Requirements

    Regulations issued by the Scottish Executive. In Northern Ireland, the current edition of the Building Regulations (Northern Ireland) issued by the Department of the Environment for Northern Ireland. In the Republic of Ireland the installation must also conform with the relevant parts of: The current editions of:- http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 5 The required fireplace, hearth, and clearance dimensions are shown in figure Page 6 For fireplace openings having dimensions different to those shown in figure 2 refer to Table 1 and BS 5871- Part 3 for flue sizes. Figure 1. Hearth and fireplace opening http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 6 Page 6 of 25 Figure 2. Hearth and fireplace opening for installations using the SPANISH BASKET CASTING ONLY Page 7 http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 7 Page 8 Into a fireplace that has a fireback of nominal size 400mm and conforming to BS1251. Into a Baxi Fires Division replacement chairbrick. Part number 0552391 Suitable flues and minimum flue sizes are as follows: - 225mm × 225mm conventional brick flue.
  • Page 8 Note the spillage test requirements detailed further on in this manual. If the fan is likely to affect the appliance, the appliance must not be installed unless the fan is permanently disconnected. http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 9 178mm from the fireplace opening. 4.15.3 Non-combustible side projections to be 75mm from the fireplace opening. 4.16 A fireguard complying with BS 8423 should be fitted for the protection of young children, the elderly, or the infirm. http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 10: Unpacking

    This is factory set. See section 11.1 (Servicing and parts replacement). 6.3 Fitting the burner tray trim. Locate the burner tray trim over the front rim of the burner tray. Push the trim fully down (See figure http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 11 The casting may be moved forward providing the front of the burner tray trim does not protrude beyond the front plane of the fireplace opening by more than 28mm (See figure http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 12: Burner And Supply Pipe Installation

    Turn on the gas supply and pressure check the installation pipework for gas soundness. In the United Kingdom (GB) check in accordance with the current edition of BS 6891. In the Republic of Ireland check in accordance with the current edition of IS 813 "Domestic Gas Installations". http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 13: Preliminary Burner Checks

    1. Check the inlet pressure by fitting a pressure gauge at the test point. The test point is on the inlet 'T' connector (See figure 7). Check the pressure with the appliance alight and set at maximum output. Figure 7. Pressure test point http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 14: Fitting The Firefront

    1. Place the ceramic base coal in the burner compartment. The bottom rear face of the coal should rest on the angled ledge at the back of the burner tray. The bottom front recess of the coal base should locate against the tags at the front of the ceramic support (See figure http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 15 Figure 10. Front coal location (Burner tray design may differ from that shown) 3. Place the right hand ceramic front coal in position in front of the base coal. This should overlap the left- hand coal. Push the two sides together to minimise the gap (See figure 10). Page 17 http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 16 6. Hold coal 'B' upright with the arrow pointing to the top. Locate coal 'B' as shown in figure Figure 12. Second row "Coal B" 7. Hold coal 'C' upright with the arrow pointing to the top. Locate coal 'C' as shown in figure http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 17 9. Hold coal 'E' upright with the arrow pointing to the top. Locate coal 'E' as shown in figure Figure 15. Second row "Coal E" 10. Hold coal 'F' upright with the arrow pointing to the top. Locate coal 'F' as shown in figure http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 18 11. Hold coal 'G' upright with the arrow pointing to the top. Locate coal 'G' as shown in figure Figure 17. Second row "Coal G" Page 19 12. Hold coal 'H' upright with the arrow pointing to the top. Locate coal 'H' as shown in figure Figure 18. Second row "Coal H" http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 19 14. Hold coal 'J' upright with the arrow pointing to the top. Locate coal 'J' as shown in figure Figure 20. Second row "Coal J" 19. Hold coal 'K' upright with the arrow pointing to the top. Locate coal 'K' as shown in figure Figure 21. Second row "Coal K" Page 20 http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 20: Full Operating Checks

    Check that the system operates properly as follows: Light the appliance. Set at the "HIGH" position and leave for one minute. Turn back to "OFF" to extinguish the pilot. Note the time when the pilot goes out. Listen for a snap http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 21: Final Commissioning

    Page 21 This monitoring system must not be adjusted, bypassed or put out of operation. This monitoring system, or any of its parts, must only be exchanged using Baxi Fires Division authorised parts. 10.3 Final commissioning. Visually inspect the appliance. Clean off any marks incurred during installation.
  • Page 22: Checking The Aeration Setting Of The Burner

    6. Lift the burner out of the fireplace opening. 7. Replace in the reverse order. 11.3 To remove the pilot unit. 1. Remove the burner unit (See section 11.2). 2. Detach the pilot pipe from the pilot unit. http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 23 Note: 1. The pilot unit is an atmosphere sensing device. It must be replaced as a whole assembly. Its individual components are not separately replaceable. Figure 25. Gas valve (Viewed from rear with burner turned over and front leg bracket removed) Page 24 http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 24: To Remove The Gas Valve

    10. Remove the gas valve 11. Refit in the reverse order. 11.5 To replace the burner. (See figure 26). Figure 26. Removal of burner 1. Remove the burner unit (See section 11.2). 2. Support the elbow injector and unscrew the injector nut. http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...
  • Page 25: To Remove The Main Burner Injector

    27). Figure 27. Main burner Injector removal 1. Remove the burner (See section 11.5). 2. Remove the burner clamping screw (See figure 3. Unscrew the injector from the burner 4. Refit in the reverse order. Page 25 http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I... 20/08/2012...