SPECIFICATIONS
Model
Height x Width x Depth
GCSF_1
36" x 40" x 40"
(9.4cm x 0.6cm x 0.6cm)
GCSF_2
74" x 40.4" x 40"
(88cm x 02.6cm x 0.6cm)
Model
Voltage
120V/60Hz
GCSF_1
120V/60Hz
GCSF_2
WATER QUALITY REQUIREMENTS
Waterline pressure and quality MUST meet Lang Manufacturing Specifications listed below.
Contact your local water equipment system provider to assist you in determining your
specific water quality, or contact Lang Technical support for assistance, 1-800-807-9054.
YOUR LOCAL WATER CONDITIONS MAY DAMAGE YOUR LANG EQUIPMENT.
FAILURE TO PROPERLY TREAT WATER MAY RESULT IN DAMAGE AND MAY VOID
SOME OR ALL OF THE WARRANTY.
WATER SPECIFICATIONS, after treatment the water must continuously be within the
following parameters.
Cold Water: 20 to 80 PSI, 3 GPH minimum capacity
pH: 6.8 to 7.6
Conductivity: <1/500,000 ohms per inch
Total dissolved solids: < 100 PPM
Hardness: 2 to 4 grains per gallon
Maximum Salinity Ion Content
Chlorine: < 0.5 PPM
•
Chlorides: < 30 PPM
•
Sulfates: < 40 PPM
•
Iron: < 0.1 PPM
•
Copper: < 0.05 PPM
•
Manganese: < 0.05 PPM
•
Chloramines: < 0.5 PPM
•
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
Call the Lang Technical Service at 1-800-48-564.
Side:0, Back: , Floor: 4
Side:0, Back: , Floor: 4
UTILITY REQUIREMENTS
Total kW
Phase
0.7
1.4
or
Clearance from
combustible surface
Amps/Line
1
5.8`
3/8" NPT, 60,000 BTU/hr
3
11.6
3/8" NPT, 120,000 BTU/hr
-IMPORTANT-
Weight
Installed Shipping Freight Class
555 lbs. 620lbs
(252 kg) (28 kg)
0 lbs. 240 lbs
(503 kg) (562 kg)
Total Gas Req.
Gas W.C. Max.
70
70
12 W.C.
12 W.C.