Abnormal temperature
System control
ASS'Y POWER
DB601
TSW601
90*C
IC601
Q601
T601
D604
ON/OFF
K6A
LAMP
Is thermal switch(TSW601) operating?
If a temperature on periphery of
Power circuit became over 90˚C, the
thermal switch will be turned off.
TSW601
OPEN : abnormal
Optical unit protect
(In the case ass'y senser-2 is damaged.)
Temp. SW
Is thermal switch(SW905) oper-
ating?
If a temperature on the
periphery of lamp reaches
100˚C, the thermal switch
Interlock
will be turned off automati-
sw
cally.
SW905
OPEN : abnormal
Fuse
AC INPUT
Temp. SW
100*C
SW905
F901
SW902
Inter lock SW
Temp. SW
Power circuit
protect
K65A
K66A
-
16V
-
7
T651
7
-16V
-
6V
- 3/4
IC651
3/4-
6V
-
S-5V
- 2
2 -
S-5V
1 - Fan-drive
- Fan - 1
PC603
drive
ON/OFF
FN905
FN902
FN903
-18-
ASS'Y SUBPOWER
IC6602
IC6604
Fan+B2
16V
FAN+B1
CLK
P-FAIL--Q6619
SDI
CS2
Fan-Drive
FAN+B2
P-FAIL--Q6619
IC6603
IC6606
Fan+B1
16V
Q6606
CLK
SDI
CS1
Fan-Drive
6V
3.3V
9V
16V
15.7V
15V
13V
ON/OFF
Power on/off signal
Power and Fan on/off signal
Fan control signal
FAN+B1
K16C
P-FAIL--Q6601
1 -
FAN+B1
3 - P-FAIL
FAN+B1
P-FAIL--Q6601
FAN+B1
FAN+B1
P-FAIL--Q6601
D1637
P-FAIL--Q6601
D1638
3
12V
IC1621
ASS'Y MOTOR DRIVE
K66C
13V
- 1
FAN+B1
- 3
P-FAIL
- 5
K66J
- 1
--FN906
- 2
K66K
- 1
--FN904
- 2
K66E
15.7V
- 1
K66D
S5V
- 1
IC RESET
- 3
P-FAIL
- 4
Fan drive
- 5
CLK
- 6
SDI
- 7
CS1
- 8
CS2
- 9
K16A
- 1
--FN901
- 2
K16B
- 1
INTAKE
--FN902
- 2
FAN
K16D
- 1
--FN903
- 2
K16E
- 1
BALLAST
--FN905
- 2
K16T
1
- 1
15.7V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents