Bosch SHE4AM12U Repair Instructions page 39

Hide thumbs Also See for SHE4AM12U:
Table of Contents

Advertisement

Digital error codes E:08 – E:13
are shown with one LED
display:
.
They have
different causes, such as faulty
heat
pump,
faulty
module or insufficient water
supply.
Troubleshooting is needed to
determine the cause.
6.1.4.5 Filling error codes
Digital display
E:14 Flow meter error
 Code not used (no flow meter)
E:15 Water in base
 Code not used (bases are open)
E:16 Volume flow without activation
 Code not used (no flow meter)
E:17 Volume flow too high
 Water volume too high, safety float
activated
E:18 Volume flow too low
 Water volume too low, heat pump
motor load too low.
 Check water supply
702_58300000130262_ara_en_c
power
LED display
Same
display shows
for error codes
E:14 – E:18.
6.1.4.6 Heat pump error codes (circulating)
Digital display
E:20 Heater error
 Heater system check failed;
functional safety error.
 Replace heat pump
E:21 Blockage
 Heat
circulate and clear blockage.
 Replace heat pump
LED
pump
unable
to
LED display
Same LED display
shows
for
error
codes E:20 – E:21.
Page 39 of 50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

She4am02ucShe5am02ucShx3am02uc

Table of Contents