CLSI Editing

Parameter # 36h
Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth
characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
NOTE Symbol length does not include start and stop characters.
Enable CLSI Editing
(01h)

NOTIS Editing

Parameter # 37h
Enable this parameter to strip the start and stop characters from a decoded Codabar symbol. Enable this feature if
the host system requires this data format.
Enable NOTIS Editing
(01h)
Symbologies 11 - 51
*
Disable CLSI Editing
(00h)
*
Disable NOTIS Editing
(00h)