5.2 Operating The Fire - Cast Tec CTTC00MN Installation, Maintenance & User Instructions

“16” inset tray decorative fuel effect gas fire
Table of Contents

Advertisement

The ceramic fuel-bed remains hot for a considerable period after use and
sufficient time should be allowed for the fire to cool before cleaning etc.
The fire must only be operated with the cast surround supplied with the fire.

5.2 Operating the Fire

To light the fire proceed as follows:-
1)
Depress the control knob and turn anti-clockwise to the position
marked pilot. Hold in the control knob for a few seconds to allow the gas to
reach the pilot.
2)
Continue to hold-in the control knob and press the igniter button. If the pilot
does not light, continue to press the igniter button until ignition occurs. When
the pilot has lit, continue to hold the control knob in for 5-10 seconds
to allow the thermocouple to heat up, if the pilot goes out when the control
knob is released, repeat the lighting sequence.
In the unlikely event of a failure of the igniter, the fire can be lit as follows :-
Depress the control knob and turn anti-clockwise to the position
marked pilot. Hold in the control knob for a few seconds to allow the gas to reach
the pilot. Insert the tip of a lit taper in behind the front ceramic coals on the left
hand side. This will light the pilot flame. When the pilot has lit, continue to hold
the control knob in for 5-10 seconds to allow the thermocouple to heat up, if the
pilot goes out when the control knob is released, repeat the lighting sequence.
3)
After lighting, turn the control knob in the anti-clockwise direction to the high
position and the main burner will light. It is recommended that for most
efficient performance the fire is allowed to warm up for a few minutes with
the gas control on maximum.
4)
The gas control can be turned clockwise from the maximum position to give
the desired heat output.
WARNING
If the fire goes out for any reason or is turned off and it is
necessary to re-light the fire it is important to allow the fire to cool
for 3 minutes before attempting to re-light it.
SPILLAGE MONITORING SYSTEM
This appliance is fitted with a spillage monitoring system which shuts down the fire
if the evacuation of combustion products from the fire is affected by a partially or
fully blocked flue. If this system operates the fire will go out. If this occurs, leave
the fire for at least three minutes then follow the lighting procedure as described in
the previous section. In the event of repeated operation a CORGI registered
gas installer must be called to investigate and rectify the cause.
20

Advertisement

Table of Contents
loading

Table of Contents