Cast Tec Integra SuperSlim Slide Control Installation And User Instructions Manual

Inset live fuel effect gas fire

Advertisement

Quick Links

Integra SuperSlim Slide Control
Inset Live Fuel Effect Gas Fire
Installation and
Users Instructions
This product is not suitable for primary
heating purposes
These instructions should be read by the
installer before installation and then should
be handed to the end user when the
installation is complete.
This is an official requirement and is the
responsibility of the fitter of this
appliance.
Having installed the appliance, the installer
should take the necessary steps to ensure
that the user fully understands how to operate
the appliance and is also made aware of the
fire's basic cleaning and maintenance
requirements.

Advertisement

Table of Contents
loading

Summary of Contents for Cast Tec Integra SuperSlim Slide Control

  • Page 1 Integra SuperSlim Slide Control Inset Live Fuel Effect Gas Fire Installation and Users Instructions This product is not suitable for primary heating purposes These instructions should be read by the installer before installation and then should be handed to the end user when the installation is complete.
  • Page 2: Table Of Contents

    CONTENTS SECTION PAGE Notes for the Installer and End User Installation Requirements Installation Procedure Commissioning Technical Data Replacement Parts Trouble Shooting (GAS SAFE Engineer Only) 8 User Instructions Cleaning and Maintenance Ignition System Wiring Diagram Fire Front Specifications Coal Layout Instructions Ripped Coal Layout Instructions Guarantee Trouble Shooting (User)
  • Page 3: Notes For The Installer And End User

    NOTES FOR THE INSTALLER AND END USER THIS APPLIANCE IS INTENDED FOR DECORATIVE PURPOSES This appliance has been designed, tested and manufactured to the European Standard EN509 relating to Decorative Gas Appliances and must be installed by a qualified GAS SAFE Registered Installer in accordance with the Gas Safety (Installation and use) regulations 1994 and all other relevant standards.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS This appliance must only be installed in Great Britain or Ireland. 1. This appliance is a natural gas appliance only and has been designed for use with the following applications: a) Class I - Conventional brick or stone chimney as used for a solid fuel fire with a cross sectional dimension of 225mm x 225mm (9”...
  • Page 5: Installation Procedure

    INSTALLATION PROCEDURE 1. Carefully lift the appliance out of the packaging taking care not to damage the ceramic components in the separate carton. 2. Remove the magnetic trim and store to one side to prevent any damage. 3. Cut the foam sealing strip (in plastic bag supplied) to length and stick a continuous strip down the two sides and across the top of the radiant box.
  • Page 6: Commissioning

    INSTALLATION PROCEDURE CONTINUED ALTERNATIVE FIXING METHOD 100mm 100mm Where the drilling of the back panel is not practical, an alternative fixing method may be employed using the optional cable fixing kit provided. Drill four holes in the rear of the fireplace opening (Fig. 5). Securely fix the four eye bolts provided using suitable rawl plugs.
  • Page 7: Technical Data

    TECHNICAL DATA Gas Type Natural Gas (G20) Cat 2H Gas Connection Number of Injectors Injector size Stereomatic 065 Control Max Operating Temperature Inlet Pressure Cold 20 mbar (8” W.G.) Heat Input (Gross) 5.5 kW Weight 10 kg REPLACEMENT PARTS 1. Front Coal & Fuel Bed - All these ceramic components can be replaced at service intervals depending on their condition.
  • Page 8: Trouble Shooting (Gas Safe Engineer Only)

    TROUBLE SHOOTING (GAS SAFE ENGINEER ONLY) 1. The Piezo will not spark. Check: The battery If the electrode is cracked or broken - Replace pilot assembly. If the HT lead is shorting out on the burner body - Locate where the short is occurring, isolate and/or re-route the lead.
  • Page 9: User Instructions

    USER INSTRUCTIONS THIS APPLIANCE IS INTENDED FOR DECORATIVE PURPOSES. Please also familiarise yourself with the Notes for the Installer and End User on page 3. OPERATION AND CONTROLS It is most important that the operator of this gas appliance has fully read and understood all the operating, cleaning and maintenance procedures as laid out in these instructions.
  • Page 10: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Legend Gas Fires recommend that this appliance is serviced at regular 12 monthly intervals. The chimney or flue should also be checked regularly to ensure that all products of combustion are entering the flue and there is no excessive build up of soot. It is the users responsibility to ensure that the appliance is kept in a clean serviceable condition.
  • Page 11: Ignition System Wiring Diagram

    IGNITION SYSTEM WIRING DIAGRAM Fig. 10A FIRE FRONT SPECIFICATIONS Fire fronts are now available in many different designs and finishes. The user can now choose their own particular style of fire front to suit their individual fireplace setting, providing the fire front complies with the following dimensions - Fire Front - (X) Max: 210mm...
  • Page 12: Coal Layout Instructions

    COAL LAYOUT INSTRUCTIONS CAUTION: The coals are extremely fragile and must be handled accordingly. Gloves should be worn and any inhalation of dust should be avoided. Never put additional coals on the fire. Never use coals other than those originally supplied, or genuine Legend Spare Parts. Fuel Bed 1.
  • Page 13 COAL LAYOUT INSTRUCTIONS CONTINUED 5. Finally check that all the coal pieces are ‘nested’ together correctly (Fig. 16). Fig. 16 It is very important that all the coals are used and arranged as shown in order to achieve the desired flame picture.
  • Page 14: Ripped Coal Layout Instructions

    RIPPED COAL LAYOUT INSTRUCTIONS CAUTION: The coals are extremely fragile and must be handled accordingly. Gloves should be worn and any inhalation of dust should be avoided. Never put additional coals on the fire. Never use coals other than those originally supplied, or genuine Legend Spare Parts. Fuel Bed 1.
  • Page 15 RIPPED COAL LAYOUT INSTRUCTIONS CONTINUED 5. Finally check that all the coal pieces are ‘nested’ together correctly (Fig. 21). Fig. 21 It is very important that all the coals are used and arranged as shown in order to achieve the desired flame picture.
  • Page 16: Guarantee

    GUARANTEE Your appliance is guaranteed for one year from proof of purchase. Should the appliance prove defective within that period we agree to repair or replace (at our discretion) the component or appliance provided that: 1. The user can produce a receipt for proof of purchase/installation. 2.