Safety instructions

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
1.
Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.
2.
Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.
4.
WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service
disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
5.
Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.
8.
WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked "acceptable for fan support" and use
mounting screws provided with the outlet box (Mounting must support at least 35 lbs.)
9.
WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do
not insert foreign object between rotating blades.
10.
Attach the mounting bracket using only the hardware supplied with the outlet box.
11.
WARNING: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.
12.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed
control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13.
Never place a switch where it can be reached from a tub or shower.
14.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit's operation. Follow the heating
15.
equipment manufacturer's guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
16.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.
17.
All set screws must be checked and tightened where necessary before installation.
Note (For Outdoor Fans Only): Suitable for use in wet locations when installed in a GFCI protected branch circuit.
1
Before you begin installing the fan, Switch
power off at Service panel and lock service
disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot
be locked, securely fasten a prominent
warning device, such
service panel.
4
Downrod Mount Installation
Loosen 2 screws on yoke to allow
down rod to slip into yoke.
2
Before installing this fan make sure the
outlet box is properly installed to the house
structure. To reduce the risk of fire, electric
shock, or personal injury, mount to outlet
box or supporting system acceptable for fan
support.
as a tag, to the
(Mounting must support at least 35 lbs.)
5
Remove keeper pin and cross
pin from yoke, and save for later
use.
3
Use metal outlet box suitable for fan support
and use only the screws provided with the
outlet box
(must support 35 lbs). Before
attaching fan to outlet box, ensure the outlet
box is securely fastened by at least two points
to a structural ceiling member ( a loose box
will cause the fan to wobble). Remove the
two outlet box screws provided with the box,
aligning the holes of the mounting bracket
with the holes of the outlet box. Re-install the
2 outlet box screws securely.
6
Place canopy over downrod.