Firebox Installation - Heatilator WS18-AU Installation Instructions Manual

Eco-choice ws series
Table of Contents

Advertisement

CORNER POSITIONING (45°)
Fig. 4
Table 2
A
Min. clearance from fi rebox corner to corner walls
B
Min. distance from center of spigot to corner walls
C
Min. distance from corner wall to fl oor protector front
D
Min. fl oor protector projection from corner wall
E
Min. fl oor protector front width
F
Min. overall fl oor protector depth

FIREBOX INSTALLATION

1. If a separate fl oor protector is being used position now. Place the fi rebox on the fl oor protector to
suit the minimum installation clearances. (See Fig 3 or 4).
2. Seismically restrain the fi rebox and the fl oor protector to the fl oor.
3. Fit 2 x 6mm fi xings suitable for the fl oor material. DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of base (optional).
February 7, 2014
B
F
FLOOR PROTECTOR
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted
7056-153A
A
E
WS Series Wood Burner
C
D
With Double
Flue Shield
Fitted
155
470
1219
730
692
1379