Floor Protector - Heatilator WS18-AU Installation Instructions Manual

Eco-choice ws series
Table of Contents

Advertisement

WS Series Wood Burner

FLOOR PROTECTOR

Heatilator WS18 does not require a insulating Floor Protector, as they are tested and comply with the
minimum Floor Protector requirements of AS/NZS 2918:2001.
Note:
▪ The minimum Floor Protector sizes are specifi ed in the clearance chart, see Table 1 & 2.
▪ A Floor Protector can include ceramic tiles with grouted joints fi xed directly onto a wooden fl oor or
a sheet of toughened glass, panel steel or any other non combustible material laid directly onto a
wooden fl oor.
▪ If installed directly onto a concrete slab, the concrete slab can be considered as the fl oor
protector,but must maintain the minimum measurement listed.
PARALLEL POSITIONING
Fig. 3
REAR WALL
G
F
FLOOR PROTECTOR
Table 1
A
Min. Clearance from back of unit to rear wall
B
Min. clearance from center of spigot to rear wall
C
Min. distance from front of base to fl oor protector front
D
Min. fl oor protector front width
E
Min. distance from rear wall to front of fl oor protector
F
Min. distance from unit side to side wall
G
Min. clearance from center of spigot to side wall
NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to
AS/NZS 2198:2001 3.2.3 TABLE 3.1
Page 4
E
D
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted
7056-153A
B
C
With Double Flue
Shield Fitted
175
345
300
800
1055
300
618
February 7, 2014