Maintenance; Maintenance Schedule; Product Specifications; Generator Specifications - Generac Power Systems XG Series Owner's Manual

5,600-6,400 watt 50 hz portable generator
Hide thumbs Also See for XG Series:
Table of Contents

Advertisement

Available languages

Available languages

Do not use the battery charger for more than 48 hours at one
charge.
Figure 13 - Battery Charger Jack
BATTERY
CHARGER
INPUT

3.1 MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil and Oil Filter‡
Clean Spark Arrestor Screen
Service Air Filter
Replace Spark Plug
Change oil after first 30 hours of operation then every season.
*
Change oil and oil filter every month when operating under heavy load or in
high temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if very dirty.

3.2 PRODUCT SPECIFICATIONS

3.2.1 GENERATOR SPECIFICATIONS

Model
Rated Max. Power ...................................................................5.6 kW**
Surge Power ...............................................................................8400W
Rated AC Voltage .............................................................................230
Rated Max AC Load
Current @ 230V .............................................................24.3 Amps**
Rated Frequency .................................................... 50 Hz @ 3000 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
Model
Rated Max. Power ...................................................................6.4 kW**
Surge Power ...............................................................................9600W
Rated AC Voltage .............................................................................230
Rated Max AC Load
Current @ 230V .............................................................27.8 Amps**
Rated Frequency .................................................... 50 Hz @ 3000 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
NOTE:
At Each Use
*Every Season/Every 100 Hours
**Every Season/Every 100 Hours
**Every Season/Every 200 Hours
Every Season
** Operating temperature range: 18° C (0° F) to 40° C ( 104° F). When operating
above 25° C (77° F), there may be a decrease in engine power.
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 305 meters (1,000 feet)
above sea level.

3.2.2 ENGINE SPECIFICATIONS

Displacement ............................................................................... 407cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Part No. ...................................................................0E7585
Spark Plug Gap ........................................................................0.76 mm
Gasoline Capacity ............................................................... 34.07 Liters
Oil Type.................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ............................................ w/ Filter Change = 1.42 Liters
Oil Filter Part No. . ....................................................................070185B
Run Time/Fuel Consumption-1/2 Load ..... 10 Hours / 3.4 Liters per hour

3.3 GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section of this manual should
be made at least once each season. Follow the requirements in the
"Maintenance Schedule".
Once a year replace the spark plug and replace the air filter.
A new spark plug and clean air filter assure proper fuel-air
mixture and help the engine run better and last longer.

3.3.1 GENERATOR MAINTENANCE

Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors. Cooling air slots in the generator must not become
clogged with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.
Never insert any object or tool through the air cooling

slots, even if the engine is not running.
DO NOT use a garden hose to clean generator. Water can
enter the engine fuel system and cause problems. In addition,
if water enters the generator through cooling air slots, some
water will be retained in voids and crevices of the rotor
and stator winding insulation. Water and dirt buildup on the
generator internal windings will eventually decrease the
insulation resistance of these windings.

Maintenance

w/o Filter Change = 1.136 Liters
NOTE:
NOTE:
11

Advertisement

Table of Contents
loading

Table of Contents