EWM-COPPER, EWM-SS, EWM-SS-BLK
If the unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.

TO REPLACE HEATER ON/OFF SWITCH

1. Unplug the unit from the outlet.
2. Remove the two mounting screws from the bottom front of the heater assembly.
3. Loosen but do not remove the four heater / light assembly mounting screws
located on the bottom sides of the wall mounted electric fireplace.
4. Slide the heater and light assembly forward to release it from the bottom of the
wall mounted electric fireplace.
5. Place heater and light assembly on a flat surface and remove the six screws from
the upper sides and back of the assembly.
6. Separate the flicker motor and light assembly from the lower assembly.
7. Locate the heater on/off switch mounted in the lower cover and disconnect the
wiring clips and connections noting their original locations.
8. Properly orientate the new switch and connect all of the wiring clips and
connections.
9. Reassemble in the reverse order as above.