ner). Connect the Regulator to the tank (with the tank valve fully closed). Although the flow of gas is stopped when
the Type 1 system is disconnected; you should always turn the L.P. tank main valve off after each use and during
transport of the tank or unit. Insert the regulator inlet into the tank valve and turn the black coupler clockwise until
the coupler tightens up.
Do not over tighten the coupler.
Purging the system:
position for about 20 seconds to allow the air in the system to purge before attempting to light the burners.
Do not attempt lighting the grill within 10 minutes after purging!
To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn
counter clockwise. The inlet will then disengage, remove the inlet from the tank valve opening if it has not already
done so when it was disengaged. Your local L.P. filling station should be equipped with the proper equipment to fill
your tank. If trading your tank in, always ensure to obtain only Type 1 20 lb cylinders with an overfill protection
device.
Turn the main tank valve on and turn the burner control valves on the unit to the " light"
L.P. Gas Hook Up (Type 1
or QCC-1 regulator):
Grill orificed for use with
L.P. gas come equipped with an L.P.
hose/regulator assembly for connec-
tion to a standard 20 lb. L.P. cylinder
(Type 1). The L.P. tank is not
included.
Connection: 1/2" NPT male with a
3/8" Flare adapter. L.P. Hose with a
quick disconnect and fittings are
included.
Operating pressure: 11.0" W.C.
Connect the 3/8" flare end of the L.P
Hose to the brass adapter on the
Manifold (underneath bottom left cor-
8